G10 Installation Guide 7.13.2
77
5
Connect G10 to the Monitored Network
Rev. 005-140228
M
ONITORED
L
INK
C
ABLING
(IIC200)
This section describes Ethernet connections and cabling for the IIC200; for
information for the IIC100, refer to
Monitored Link Cabling (IIC100)
To accurately monitor links, a minimum signal strength is required at each G10 input port. The
signal strength requirement is broad enough to allow some optical taps and splitters. The
inputs must comply with
and can be verified with optical light
meters.
IIC200 Ethernet Connections
The IIC200 has 8 ports which can be used for 1G Ethernet connections. Ports 5-8 are dual-
purpose sockets which can be used for either 1G or 10G Ethernet connections (
).
If your configuration pairs the TRM100 RTM with the IIC200, connect the 10G inputs to
the IIC200, NOT the TRM100 RTM
.
Figure 5.1 - IIC200 Ethernet Connections
Refer to
for details about installing and maintaining SFP
modules.
4 1G/10G Dual-Purpose Connections
4 1G Connections