DISPLAY Commands
The DISPLAY commands deal with the front-panel menu display.
:DISPlay
:DISPlay:BACKlight
ENA | DIS
Enables/disables the Menu Display backlight.
:
DISPlay:BACKlight?
Returns the current status of the backlight.
:DISPlay:CONTrast
<numeric_value>
Controls the intensity of the front-panel menu display. The value
should be an integer number between 1 and 255. One has the least
amount of contrast, while 255 has the maximum amount of contrast.
:DISPlay:CONTrast?
Returns the current contrast value.
INPUT Commands
The INPUT commands deal with the genlock input signal (the only signal input
to the SPG 422.)
:INPut
:INPut:CONFigure
TERM1 | TERM2 | LOOP12
Determines the configuration of the genlock inputs on the rear panel.
The options are terminate input 1, terminate input 2, or loopthrough.
:INPut:CONFigure?
Returns the current configuration of the genlock input. It returns
either TERM1, TERM2, or LOOP12.
:INPut:FIELd
<numeric_value>
Determines the genlock field advance or delay. This command
affects the timing of all output signals. The options are +2, +1, 0, –1,
or –2 (2 fields advance to 2 fields delay).
:INPut:FIELd?
Returns the current field level offset as a string, where the value is
absolute and advance or delay is stated in the following text. For
instance, setting to –2 will return
“2 Fields of Advance.”
Summary of Contents for B020000
Page 4: ......
Page 15: ...Getting Started...
Page 16: ......
Page 25: ...Operating Basics...
Page 26: ......
Page 32: ...Operating Basics 2 6 SPG422 Component Digital Sync Generator User Manual...
Page 33: ...Reference...
Page 34: ......
Page 92: ...Reference 3 58 SPG422 Component Digital Sync Generator User Manual...
Page 93: ...Appendices...
Page 94: ......
Page 144: ...Specifications A 50 SPG422 Component Digital Sync Generator User Manual...