Be sure your work area meets applicable ergonomic standards. Consult with an ergonomics professional to
avoid stress injuries.
Use care when lifting and carrying the product. This product is provided with a handle or handles for lifting
and carrying.

Warning: The product is heavy. To reduce the risk of personal injury or damage to the device get
help when lifting or carrying the product.

Warning: The product is heavy. Use a two-person lift or a mechanical aid.

Use only the Tektronix rackmount hardware specified for this product.

Probes and test leads

Before connecting probes or test leads, connect the power cord from the power connector to a properly grounded power outlet.

Keep fingers behind the protective barrier, protective finger guard, or tactile indicator on the probes.

Remove all probes, test leads and accessories that are not in use.

Use only correct Measurement Category (CAT), voltage, temperature, altitude, and amperage rated probes, test leads, and adapters for
any measurement.

Beware of high voltages

Understand the voltage ratings for the probe you are using and do not exceed those ratings. Two ratings are
important to know and understand:

• The maximum measurement voltage from the probe tip to the probe reference lead
• The maximum floating voltage from the probe reference lead to earth ground

These two voltage ratings depend on the probe and your application. Refer to the Specifications section of
the manual for more information.

Warning: To prevent electrical shock, do not exceed the maximum measurement or maximum
floating voltage for the oscilloscope input BNC connector, probe tip, or probe reference lead.

Connect and disconnect
properly

Connect the probe output to the measurement product before connecting the probe to the circuit under test.
Connect the probe reference lead to the circuit under test before connecting the probe input. Disconnect the
probe input and the probe reference lead from the circuit under test before disconnecting the probe from the
measurement product.

Connect and disconnect
properly

De-energize the circuit under test before connecting or disconnecting the current probe.

Connect the probe reference lead to earth ground only.
Do not connect a current probe to any wire that carries voltages or frequencies above the current probe
voltage rating.

Inspect the probe and
accessories

Before each use, inspect probe and accessories for damage (cuts, tears, or defects in the probe body,
accessories, or cable jacket). Do not use if damaged.

Ground-referenced
oscilloscope use

Do not float the reference lead of this probe when using with ground-referenced oscilloscopes. The
reference lead must be connected to earth potential (0 V).

Floating measurement use

Do not float the reference lead of this probe above the rated float voltage.

Important safety information

AWG5200 Series Arbitrary Waveform Generators Service Manual 

6

Summary of Contents for AWG5200 Series

Page 1: ...AWG5200 Series Arbitrary Waveform Generators Service Manual Register now Click the following link to protect your product www tek com register P 077174500 077 1745 00...

Page 2: ...ued and pending Information in this publication supersedes that in all previously published material Specifications and price change privileges reserved TEKTRONIX and TEK are registered trademarks of...

Page 3: ...g 12 Exterior inspection 12 Exterior cleaning 12 Lubrication 13 Remove and replace 13 Remove and replace procedures not requiring factory calibration 13 Software upgrades 15 Calibration 15 Diagnostics...

Page 4: ...the country of use Use proper power cord Use only the power cord specified for this product and certified for the country of use Do not use the provided power cord for other products Use proper voltag...

Page 5: ...damaged or operates incorrectly If in doubt about safety of the product turn it off and disconnect the power cord Clearly mark the product to prevent its further operation Before use inspect voltage...

Page 6: ...depend on the probe and your application Refer to the Specifications section of the manual for more information Warning To prevent electrical shock do not exceed the maximum measurement or maximum fl...

Page 7: ...rotective panels soldering or replacing components Verify safety after repair Always recheck ground continuity and mains dielectric strength after performing a repair Terms in the manual These terms m...

Page 8: ...als all capitals etc in the manual as is used on the instrument front panel and menus Instruction steps are numbered unless there is only one step Bold text refers to specific interface elements that...

Page 9: ...loads AWG5200 Series Rackmount Instructions GF RACK3U 071 3534 XX This document provides instructions to mount the AWG5200 Series Arbitrary Waveform Generators into a standard 19 inch equipment rack w...

Page 10: ...receive clock and trigger timing and play out waveform data via an eight lane high speed serial interface JESD204B to the DAC The DAC creates the waveform The DAC output has four different paths DC Hi...

Page 11: ...ge from electrostatic discharge Static voltages of 1 kV to 30 kV are common in unprotected environments CAUTION Static discharge can damage any semiconductor component in this instrument Observe the f...

Page 12: ...s a guide An instrument that appears to have been dropped or otherwise abused should be checked thoroughly to verify correct operation and performance Immediately repair defects that could cause perso...

Page 13: ...us injury or death Required equipment The following table lists equipment that you will need to remove and replace instrument modules Table 3 Required tools for removal and replacement of modules Name...

Page 14: ...e holes in the handle with the posts on the instrument Attach the handle with two T25 screws and torque to 20 in lbs Side handle 1 Remove the four screws using T20 bit to remove the two handle top cap...

Page 15: ...onnel If the front panel or rear panel is opened a full factory calibration must be performed by Tektronix Restore Factory calibration If you run a self cal and the results are bad you can restore the...

Page 16: ...on a unit copy C ProgramData Tektronix AWG AWG5200 Logs to a another location Review this data with an XML editor or Excel spreadsheet to locate the errors Then when you run diagnostics or calibration...

Page 17: ...Diagnostics Calibration you open a window where you can run the Self Calibration or Diagnostics The screen shows the last time that calibration ran and the internal temperature of the instrument when...

Page 18: ...mensions six or more inches greater than the dimensions of the instrument Use a shipping carton that has a test strength of at least 50 pounds 23 kg b Surround the module with a protective anti static...

Page 19: ...rd accessories for these products are listed in your user manual The user manual is available at www tek com manuals Changes to Tektronix products are sometimes made to accommodate improved components...

Page 20: ...ction contains a list of the replaceable mechanical and or electrical components Use this list to identify and order replacement parts The following table describes each column in the parts list Parts...

Page 21: ...er to Figure 1 on page 21 1 348 2037 XX 4 FOOT REAR CORNER SAFETY CONTROLLED 2 211 1481 XX 4 SCREW MACHINE 10 32X 500 PANHEAD T25 WITH BLUE NYLOK PATCH 3 211 1645 XX 2 SCREW MACHINE 10 32X 750 FLATHEA...

Page 22: ...OK PATCH 9 348 2199 XX 4 CUSHION FOOT SANTOPRENE 4 BLACK 101 80 10 211 1645 XX 6 SCREW MACHINE 10 32X 750 FLATHEAD 82 DEG TORX 20 WITH THREAD LOCKING PATCH 11 367 0599 XX 2 HANDLE ASSY BASE AND GRIP S...

Reviews: