Summary of Contents for AWG5012B Option 09

Page 1: ...s underutilized and idle equipment along with credit for buybacks and trade ins Custom engineering so your equipment works exactly as you specify Critical and expedited services Leasing Rentals Demos In stock Ready to ship TAR certified secure asset solutions Expert team I Trust guarantee I 100 satisfaction All trademarks brand names and brands appearing herein are the property of their respective...

Page 2: ...x AWG5012B Option 09 and AWG50BUP Option S39 TTL Event to TekLink LVDS Connector Adapter ZZZ User Manual P071267400 071 2674 00 ...

Page 3: ......

Page 4: ...AWG5012B Option 09 and AWG50BUP Option S39 TTL Event to TekLink LVDS Connector Adapter ZZZ User Manual xx www tek com 071 2674 00 ...

Page 5: ...ion in this publication supersedes that in all previously published material Specifications and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc TekLink is a registered trademark of Tektronix Inc Contacting Tektronix Tektronix Inc 14150 SW Karl Braun Drive P O Box 500 Beaverton OR 97077 USA For product information sales service and technical support In ...

Page 6: ...s taxes and any other charges for products returned to any other locations This warranty shall not apply to any defect failure or damage caused by improper use or improper or inadequate maintenance and care Tektronix shall not be obligated to furnish service under this warranty a to repair damage resulting from attempts by personnel other than Tektronix representatives to install repair or service...

Page 7: ......

Page 8: ...mental Considerations viii Preface ix Key Features ix Software Upgrades x Related Documents x Installation 1 Products 1 Parts List 1 Controls and Connectors 2 Table Event Input Connector 3 Connecting Cables 5 Mounting the Connector Adapter 6 Specifications 7 TTL Event to TekLink LVDS Connector Adapter User Manual i ...

Page 9: ...Table of Contents ii TTL Event to TekLink LVDS Connector Adapter User Manual ...

Page 10: ... fire or shock hazard observe all ratings and markings on the product Consult the product manual for further ratings information before making connections to the product The inputs are not rated for connection to mains or Category II III or IV circuits Do not apply a potential to any terminal including the common terminal that exceeds the maximum rating of that terminal Do not operate without cove...

Page 11: ...oss of life CAUTION Caution statements identify conditions or practices that could result in damage to this product or other property Symbols and terms on the product These terms may appear on the product DANGER indicates an injury hazard immediately accessible as you read the marking WARNING indicates an injury hazard not immediately accessible as you read the marking CAUTION indicates a hazard t...

Page 12: ...General safety summary The following symbol s may appear on the product TTL Event to TekLink LVDS Connector Adapter User Manual v ...

Page 13: ...C requirements for electrical equipment for measurement control and laboratory use 1 2 CISPR 11 2003 Radiated and conducted emissions Group 1 Class A IEC 61000 4 2 2001 Electrostatic discharge immunity IEC 61000 4 3 2002 RF electromagnetic field immunity IEC 61000 4 4 2004 Electrical fast transient burst immunity IEC 61000 4 5 2001 Power line surge immunity IEC 61000 4 6 2003 Conducted RF immunity...

Page 14: ...high quality shielded interface cables should be used 3 Performance Criterion C applied at the 70 25 cycle Voltage Dip and the 0 250 cycle Voltage Interruption test levels IEC 61000 4 11 Australia New Zealand Declaration of Conformity EMC Complies with the EMC provision of the Radiocommunications Act per the following standard in accordance with ACMA CISPR 11 2003 Radiated and Conducted Emissions ...

Page 15: ...ent and to reduce the use of natural resources we encourage you to recycle this product in an appropriate system that will ensure that most of the materials are reused or recycled appropriately This symbol indicates that this product complies with the applicable European Union requirements according to Directives 2002 96 EC and 2006 66 EC on waste electrical and electronic equipment WEEE and batte...

Page 16: ...rm generator AWG5012B TekLink connector TTL to LVDS converter box Generator TTL signal Key Features The AWG5012B Option 09 supports the following features Subsequence Table jump NOTE The AWG software must be version 3 3 or later to enable the Option 09 features To check the software version of your AWG5012B select Help About Tektronix AWG from the menu bar TTL Event to TekLink LVDS Connector Adapt...

Page 17: ...out Use these documents Installation and operation overviews Quick Start User Manual Provides general operating information In depth operation and user interface help User online help Provides detailed instructions for using instrument functions Access the user online help from the Help button or Help menu for information on controls and elements on screen Programmer commands Programmer online hel...

Page 18: ...onnector Adapter can be used only with the AWG5012B AWG5012B Option 09 Subsequence and Table Jump AWG50BUP Option S39 Upgrade to Option 09 for the AWG5012B Parts List Table 1 AWG5012B Option 09 Description Part number Quantity Converter Box TTL Event to LVDS TekLink Connector Adapter 850 0108 xx 1 each TekLink Cable 200 cm 174 5019 xx 1 each User Manual printed 071 2674 xx 1 each TTL Event to TekL...

Page 19: ...50 0108 xx 1 each AWG5000B and AWG7000B Series Product Software CD 020 2945 xx 1 each TekLink Cable 200 cm 174 5019 xx 1 each User Manual printed 071 2674 xx 1 each Controls and Connectors 1 Table Event Input connector See page 3 Table Event Input Connector 2 TekLink connector 2 TTL Event to TekLink LVDS Connector Adapter User Manual ...

Page 20: ... standard 9 pin D type By connecting the connector adapter to your AWG5012B the instrument can accept four bit Table Jump signals The Table Jump can define up to 16 possible logic levels of the Event Input lines Pin NO 1 2 3 4 5 6 7 8 9 Signal STROBE EVENT Bit3 EVENT Bit2 EVENT Bit1 EVENT Bit0 GND GND GND GND Direction INPUT INPUT INPUT INPUT INPUT TTL Event to TekLink LVDS Connector Adapter User ...

Page 21: ...ent signals are found When Strobe is set to On the instrument reads the event signals when the strobe signal goes to low state Enable and updates the event value if a state transition in the event signals are found NOTE You cannot toggle the Strobe signal on and off using the screen interface or remote commands The Strobe definition in the sequence file can control the strobe signal input For more...

Page 22: ...r off your instrument The power is supplied from your AWG5012B through a TekLink cable 1 Connect a TTL level signal to the Table Event Input connector 2 Use a TekLink cable to connect the connector adapter and your AWG5012B TTL Event to TekLink LVDS Connector Adapter User Manual 5 ...

Page 23: ... 2 Refer to the dimensions shown in the illustration and drill holes in the mounting surface for two screws CAUTION Using screws that are too long will damage the internal circuitry Screws should enter the chassis 0 4 in 1 03 cm 3 Mount the connector adapter using two 6 32 screws of appropriate length NOTE Some rackmount kits have provisions for mounting accessories such as the connector adapter 6...

Page 24: ...ctable Minimum pulse width 64 ns Latency to analog output typical Max 650 ns 1 2 Gsps Max 1300 ns 650 Msps From D type connector on the TTL to LVDS converter to Analog output when Asynchronous Jump is selected Hold off time typical Maximum 500 sample clock cycles when Asynchronous Jump is selected TTL Event to TekLink LVDS Connector Adapter User Manual 7 ...

Page 25: ...al 1 Event signal 0 Event signal Signal ground GND Signal ground GND Signal ground GND Signal ground GND Input level TTL level Input voltage range 0 V to 5 V High level input voltage 2 V to 5 V Low level input voltage 0 V to 0 8 V Input impedance Pull up to 4 5 V by 2 2 kΩ register Output connector type 40 pin TekLink connector Output level LVDS 8 TTL Event to TekLink LVDS Connector Adapter User M...

Page 26: ...mum wet bulb temperature 29 C Altitude Operating Up to 3 000 m approximately 10 000 feet Maximum operating temperature decreases 1 C each 300 m above 1 5 km Nonoperating Up to 12 000 m approximately 40 000 feet Physical characteristics Characteristic Description Height typical 47 8 mm 1 882 in Width typical 134 4 mm 5 291 in Depth typical 134 0 mm 5 275 in Weight typical 600 g 1 32 lb TTL Event to...

Page 27: ...quipment Have surplus equipment taking up shelf space We ll give it a new home Learn more Visit us at artisantg com for more info on price quotes drivers technical specifications manuals and documentation Artisan Scientific Corporation dba Artisan Technology Group is not an affiliate representative or authorized distributor for any manufacturer listed herein We re here to make your life easier How...

Reviews: