Clear and sanitize procedures
Media and data export devices
The following table lists the data export devices in the standard instrument and
listed options. Detailed procedures to disable these devices, if any, are shown
following the table.
Table 3: Media and data export devices
Type and min.
size
Function
User
modi
fi
able
Data Input method
Location
Process to disable
USB host port
Supports
removable USB
memory device to
save setups and
waveforms.
Yes
User writeable
Front panel
Files can be deleted or overwritten
on the arbitrary/function generator or
a PC; USB memory device can be
removed and destroyed. The USB host
port cannot be disabled.
USB device port
Supports remote
control and data
transfer to PC.
None
Remote control via
USB TMC
Rear panel
The USB device port cannot be
disabled.
LAN Ethernet
1
Supports remote
control and data
transfer to PC.
None
Remote control via
VXI-11
Rear panel
The Ethernet port can be disabled.
Set “0.0.0.0” as IP Address and
Subnet Mask under Utility-I/O
Interface-Ethernet.
GPIB
1
Supports remote
control and data
transfer to PC.
None
Remote control via
IEEE488.2
Rear panel
The GPIB can be disabled. Select
Off Bus as Utility-I/O Interface-
GPIB-Con
fi
guration.
1
This device is only available on AFG2021 instruments with option GL.
AFG2000 Series Declassi
fi
cation and Security Instructions
3