Appendix C: Options
94
764 Digital Audio Monitor User Manual
Option 02 instruments are set during manufacture for fixed
output; refer to Configuring the Output on page 95 for
information about changing the setting.
When outputting to an unbalanced load (0 to 2.0 V
RMS
variable
output only), you must connect one of the lines to ground; refer to
Connecting the Instrument on page 97 for more information.
H
The analog outputs supercede the digital XLR loop-throughs;
always leave the TERM switches of Option 02 instruments set to
110
W
for proper XLR input termination.
Table 31 lists and describes important Option 02 characteristics.
Table 31: Option 02 characteristics
Characteristic
Description
Output Level
With 0 dBFS 1 kHz sine wave applied to the input
Fixed gain
+24 dBm +1.6/–0.0 dBm into 600
W
balanced
Variable gain,
high output
+24 dBm (volume control fully clockwise) into
600
W
balanced
Variable gain,
low output
2.0 V
RMS
(volume control fully clockwise) into
≥
10 k
W
Output impedance, typical
50
W
Frequency Response
±
2 dB, 20 Hz to 20 kHz
Distortion, THD+N
<
0.05% (22 kHz THD+N bandwidth)
Distortion, typical, THD+N,
variable gain, high output
<
0.005% at 1 kHz (control fully clockwise, load
≥
10 k
W
, 22 kHz THD+N bandwidth)
Summary of Contents for 070-8811-08
Page 9: ...Table of Contents vi 764 Digital Audio Monitor User Manual ...
Page 13: ...General Safety Summary x 764 Digital Audio Monitor User Manual ...
Page 57: ...Operating Basics 42 764 Digital Audio Monitor User Manual ...
Page 97: ...Appendix A Specifications 82 764 Digital Audio Monitor User Manual ...
Page 115: ...Appendix C Options 100 764 Digital Audio Monitor User Manual ...