www.tek-trol.com
9
Volume weight for whole package 12kg
Power
100H
3 AAA built-in Ni-MH batteries 1.2V (for over 12 hours of
operation) 90V-260V AC adapter
Power Consumption
1.5W
Environment Temperature
Convertor: -4°F to 140 °F (-20 to 60°C)
Flow Transducer: -22°F to 320°F ( -30 to 160°C)
Environment Humidity
Convertor: 85% RH
Protection Class
Flow Transducer: IP67
Clamp-On
HS-type: for pipe size ½"- 4" (12.5mm -100 mm)
HM-type: for pipe size 2"- 28" (50mm- 700 mm)
Other pipe size available on request
Types
Following Liquids transmit sound wave:
•
Single liquid such as, Water (Hot water, Chilled water, City
Water, Sea Water, Wastewater, etc.)
•
Sewage with small particle content
•
Oil (crude oil, lubricating oil, diesel oil, fuel oil, etc.)
•
Chemicals (alcohol, etc.)
•
Plant Effluent
•
Beverage
•
Ultra-pure liquids
Process Temperature
-22°F to 320°F ( -30°C to 160°C)
Pipe Material
Steel, Stainless Steel, Cast Iron, Copper, Cement Pipe, PVC,
Aluminum, Glass Steel Product, Liner is allowed
Pipe Size
1/2" to 28"
Pipe Straight Run
Transducer installation should be satisfied: upstream10D,
downstream 5D, 30D from the pump
Dimensions
8”X 3¾” X 1¼” (200 X 93 X 32mm) (Convertor)
2.3.2
Technical Specifications for Sensors
Types Of Sensors
S1
M1
HS
HM
Image
Order No. Sensor
S1 (Optional)
M1(Optional)
HS
HM
Order no. hand-
held
sensor
Tek-Clamp 1200A-
100H
Tek-Clamp 1200A-
100H
---------
--------
Sensor cable
length
5m
5m
5m
5m
Nominal diameter
DN 15 … DN 100
0.787
”
DN 50 … DN 700
2.24”… 28.34”
DN 15 … DN 100 20
… 4.25”
DN 50 … DN 700 57
… 28.34”
Liquid
temperature
-86
◦
F to 320
◦
F
-86
◦
F to 320
◦
F
-86
◦
F to 320
◦
F
-86
◦
F to 320
◦
F