![TEKTELIC Communications T0005982 User Manual Download Page 20](http://html.mh-extra.com/html/tektelic-communications/t0005982/t0005982_user-manual_1077275020.webp)
LoRa Agriculture Sensor User Guide
T0005978_UG
Version # 1.9
TEKTELIC Communications Inc.
Confidential
Page 20 of 22
Figure 8 LED Location
During the boot and join procedure:
Both LEDs will come on briefly when power is first applied.
After a small delay (
< 1
second) the LEDs will turn off and one of them will blink briefly.
o
If the System (green) LED blinks, then all health checks on the board have
passed.
o
If the LoRa LED (red) blinks, then one of the health checks has failed. Consider
replacing the battery, or moving the sensor to an environment within the
temperature range.
Immediately after the delay, the join procedure will begin. During the time the System
LED will blink continuously until the sensor joins a network.
The LoRa LED will now blink whenever LoRa activity occurs on the sensor (transmitting
or receiving packets).
During normal operation:
The LoRa LED will blink whenever LoRa activity occurs on the sensor (transmitting or
receiving packets)
The System LED can be controlled via the downlink command interface.