![TEKTELIC Communications T0005982 User Manual Download Page 16](http://html.mh-extra.com/html/tektelic-communications/t0005982/t0005982_user-manual_1077275016.webp)
LoRa Agriculture Sensor User Guide
T0005978_UG
Version # 1.9
TEKTELIC Communications Inc.
Confidential
Page 16 of 22
Figure 5 Reed switch location
Here are the steps as illustrated in Figure 6:
1.
Attach the magnet to the enclosure at the magnet sign, and hold it for at least 3
sec but less than 10 sec.
2.
Keep the magnet away for at least 3 sec.
As soon as the specified magnetic pattern is applied to the Agriculture Sensor, the
Agriculture Sensor is reset and tries to join the network. It may take about 10 sec from
the Agriculture Sensor reset to seeing the LED activity showing join attempts. Therefore,
as step 1 in the above is completed, it takes about 13 seconds before observing the LED
activity (if step 2 is respected).
Figure 6 Agriculture Sensor magnetic reset/wake-up pattern
3 sec
> 3 sec
< 10 sec
t
Pattern starts
Pattern ends
Magnet Present
Magnet Absent
Keep magnet attached
for at least 3 sec but
no longer than 10 sec
Magnet removed
Module reset
(and activated if
in DEEP SLEEP)