TEKTELIC Communications Kona All-in-One Home Sensor Series User Manual Download Page 4

Kona All-in-One Home Sensor User Guide 

T0005370_UG 

 

                        Version 0.5 

TEKTELIC Communications Inc. 

Confidential 

Page 5 of 32 

 

 

10.1

 

Précautions de sécurité .................................................................................................. 23

 

10.2

 

Déballage et inspection .................................................................................................. 23

 

10.3

 

Équipement requis pour l'installation ............................................................................ 23

 

10.4

 

Kona tout-en-un Accueil capteur de montage ............................................................... 23

 

10.5

 

Installation du câble de connecteur externe ................................................................. 24

 

11

 

Mise sous tension et mise en service et surveillance............................................................ 26

 

11.1

 

Équipement requis ......................................................................................................... 26

 

11.2

 

Marche / Arrêt Procédure .............................................................................................. 26

 

12

 

Fonctionnement, alarmes et gestion .................................................................................... 27

 

12.1

 

Configuration .................................................................................................................. 27

 

12.2

 

Configuration par défaut ................................................................................................ 27

 

12.3

 

Comportement des LED ................................................................................................. 27

 

13

 

Remplacement de la Batterie ................................................................................................ 29

 

14

 

Déclarations de conformité ................................................................................................... 31

 

 

Summary of Contents for Kona All-in-One Home Sensor Series

Page 1: ...ment is subject to change without notice The material herein is solely for information purposes and does not represent a commitment by TEKTELIC or its representatives TEKTELIC has prepared the information contained in this document solely for use by its employees agents and customers Dissemination of this information and or concepts to other parties is prohibited without the prior written consent ...

Page 2: ...1 Jan 31 2018 Obsolete D Smith First release 0 2 Feb 12 2018 Obsolete Z Herasymiuk Added Compliance Statements 0 3 Feb 14 2018 Obsolete D Smith Added extra safety disclaimers installation equipment and removed network server provisioning guide 0 4 Mar 29 2018 Obsolete K Strom Added section for battery replacement 0 5 Apr 02 2018 Approved S M Added more battery information ...

Page 3: ...d Equipment for Installation 11 3 4 Kona All In One Home Sensor Mounting 11 3 5 External Connector Cable Installation 12 4 Power UP and Commissioning and Monitoring 13 4 1 Required Equipment 13 4 2 Power Up Down Procedure 13 5 Operation Alarms Management 14 5 1 Configuration 14 5 2 Default Configuration 14 5 3 LED Behaviour 14 6 Battery Replacement 15 7 Compliance Statements 17 8 Description du pr...

Page 4: ...lation 23 10 4 Kona tout en un Accueil capteur de montage 23 10 5 Installation du câble de connecteur externe 24 11 Mise sous tension et mise en service et surveillance 26 11 1 Équipement requis 26 11 2 Marche Arrêt Procédure 26 12 Fonctionnement alarmes et gestion 27 12 1 Configuration 27 12 2 Configuration par défaut 27 12 3 Comportement des LED 27 13 Remplacement de la Batterie 29 14 Déclaratio...

Page 5: ... T0004886 HOME SENSOR MODULE NA EXTERNAL CONNECTION NA T0004893 HOME SENSOR MODULE NA BASE NA The Kona All in One Home Sensor line supports the following sensing applications Movement Detection Configurable triggers allow the sensor to detect if it has been moved Digital On Off Sensing An internal magnetic switch or external contact can be used to monitor on off states and count events Light detec...

Page 6: ...KTELIC Communications Inc Confidential Page 7 of 32 Figure 1 Kona All in One Home Sensor 1 2 Physical Interfaces Figure 2 illustrates the I O layout for the Kona All in One Home Sensor All models share the same layout though only functional I O is exposed on the case ...

Page 7: ...ir mating connectors are listed in Table 2 Table 2 Kona All in One Home Sensor Interface Connector Types Interface QTY Connector Type Mating Connector External Connector 0 or 1 JST B2B ZR LF SN JST ZHR 2 1 3 Specifications The Kona All in One Home Sensor specifications are listed in Table 3 Humidity Sensor Aperture LoRa LED Magnetic Switch External Connector PIR Lens PIR model only Light Sensor Sy...

Page 8: ... 42 mm 1 65 wide x 42 mm 1 65 deep x 14mm 0 55 tall Weight 20g 0 71 oz Operating Temperature 10 C to 40 C 50 F to 104 F Ingress Protection IP30 Battery CR2450 replaceable Panasonic Model CR2450 Sony Model CR2450B EVE Energy Model CR2450 FDK Corporation Model CR2450 Regulatory Compliance IEC 60950 1 CE ETSI EN 300 019 2 1 300 019 2 2 ETSI EN 300 019 2 3 300 019 2 4 FCC 15 247 RSS 247 FCC 15 209 RSS...

Page 9: ...n One Home Sensor User Guide T0005370_UG Version 0 5 TEKTELIC Communications Inc Confidential Page 10 of 32 2 What is in the Box 2 1 Product and installation material Kona All In One Home Sensor Mounting Bracket ...

Page 10: ...packing and Inspection The following should be considered during the unpacking of a new Kona All in One Home Sensor 1 Inspect the shipping carton and report any significant damage to TEKTELIC 2 Unpacking should be conducted in a clean and dry location when possible 3 Do not discard the shipping box or foam inserts as they will be required if a unit is returned for repair or re configuration 3 3 Re...

Page 11: ...hes to the 2 pin connector located on the top of the Home Sensor Figure 3 Kona All in One Home Sensor External Connector Signals Figure 3 Kona All in One Home Sensor External Connector shows the external connector signal locations The connector is designed to be attached to an open drain output however the signal line can also be driven with digital signals at 1 8V logic levels Connection cable le...

Page 12: ...ssioning and Monitoring 4 1 Required Equipment No special equipment is required to power on the Kona All in One Home Sensor 4 2 Power Up Down Procedure Once the sensor information has been added to the NS pull the tab to engage the battery To reset or turn off the device the battery must be removed refer to the Battery Replacement Section ...

Page 13: ...tuation 5 3 LED Behaviour During Boot and Join Procedure Both LED s will come on briefly when power is first applied After a small delay 1 second the LED s will turn off and one of them will blink briefly o If the System LED blinks then all health checks on the board passed o If the LoRa LED blinks then one of the health checks failed Consider replacing the battery or moving the sensor to an envir...

Page 14: ...R2450 FDK Corporation Model CR2450 In order to access the battery the two screws securing the case must be removed The screws are accessible on the bottom of the sensor case and require a T 3 Torx screwdriver Opening the case Remove the two T 3 screws on the bottom of the case While holding the sensor with the bottom facing up remove the bottom of the case With the bottom removed the coin cell hol...

Page 15: ... shown below o The top of the coin cell is marked with a symbol indicating the positive terminal This positive terminal must face up when replacing the cell Push the other end of the cell into the holder until it clips positively into the holder When reinserting battery ensure the metal hooks on the battery holder are above the battery before pushing it in Failure to do so will damage the power le...

Page 16: ...cted Consult the dealer or an experienced radio TV technician for help To comply with FCC exposure limits for general population uncontrolled exposure this device should be installed at a distance of 20 cm from all persons and must not be co located or operating in conjunction with any other transmitter Industry Canada This Device complies with Industry Canada License exempt RSS standard s Operati...

Page 17: ...OME SENSOR MODULE NA PIR NA T0004886 HOME SENSOR MODULE NA EXTERNAL CONNECTION NA T0004893 HOME SENSOR MODULE NA BASE NA La gamme de capteurs domestiques tout en un Kona prend en charge les applications de détection suivantes Détection de mouvement Les déclencheurs configurables permettent au capteur de détecter s il a été déplacé Détection numérique marche arrêt Un interrupteur magnétique interne...

Page 18: ...e externe Kona All in One Home Sensors Tous les modèles partagent le même facteur de forme mécanique Figure 1 Capteur maison Kona tout en un 8 2 Interfaces physiques La Figure 2 illustre la configuration des E S pour le capteur Home Kona All in One Tous les modèles partagent la même disposition mais seules les E S fonctionnelles sont exposées sur le boîtier ...

Page 19: ...riés dans le Tableau 2 Tableau 2 Types de connecteurs d interface de capteur domestique tout en un Kona Interface QTY Type de connecteur Connecteur compatible Connecteur externe 0 or 1 JST B2B ZR LF SN JST ZHR 2 8 3 Caractéristiques Les spécifications du capteur domestique tout en un Kona sont indiquées dans le tableau 3 Ouverture du capteur d humidité LoRa LED Interrupteur magnétique Connecteur e...

Page 20: ...rgeur x 42 mm 1 65 profondeur x 14mm 0 55 grand Poids 20g 0 71 oz Température de fonctionnement 10 C to 40 C 50 F to 104 F Protection contre la pénétration IP30 Batterie CR2450 replaceable Panasonic modèle CR2450 Sony modèle CR2450B EVE Energy modèle CR2450 FDK Corporation modèle CR2450 Conformité réglementaire IEC 60950 1 CE ETSI EN 300 019 2 1 300 019 2 2 ETSI EN 300 019 2 3 300 019 2 4 FCC 15 2...

Page 21: ... Sensor User Guide T0005370_UG Version 0 4 TEKTELIC Communications Inc Confidential Page 22 of 32 9 Qu est ce qu il y a dans la boite 9 1 Produit et matériel d installation Capteur maison Kona tout en un Support de montage ...

Page 22: ...ts à l écart de tous les enfants Les petits aimants peuvent poser un sérieux risque d étouffement Si plusieurs aimants sont avalés contactez immédiatement un médecin 10 2 Déballage et inspection Les éléments suivants doivent être pris en compte lors du déballage d un nouveau capteur domestique Kona tout en un 1 Inspectez le carton d expédition et signalez tout dommage important à TEKTELIC 2 Le déb...

Page 23: ... capteur Home sur le support et tomber Il n y a pas de problème d orientation lorsque le capteur d ambiance est monté sur une surface horizontale 10 5 Installation du câble de connecteur externe L installation du capteur Home Tout en un Kona avec connexion externe nécessite une connexion à l appareil externe Le câble du périphérique externe se branche sur le connecteur à 2 broches situé sur le des...

Page 24: ...One Home Sensor indique les emplacements des signaux du connecteur externe Le connecteur est conçu pour être connecté à une sortie à drain ouvert mais la ligne de signal peut également être pilotée avec des signaux numériques à des niveaux logiques de 1 8 V La longueur du câble de connexion ne doit PAS dépasser 3 mètres Ne pas connecter à un appareil extérieur ...

Page 25: ...nce 11 1 Équipement requis Aucun équipement spécial n est requis pour alimenter le capteur domestique tout en un Kona 11 2 Marche Arrêt Procédure Une fois les informations du capteur ajoutées au NS tirez sur la languette pour engager la batterie Pour réinitialiser ou éteindre l appareil la batterie doit être retirée reportez vous à la section Remplacement de la batterie ...

Page 26: ...nement 1 12 3 Comportement des LED Au cours de la procédure de démarrage et de jointure Les deux voyants s allument brièvement lors de la première mise sous tension Après un court délai 1 seconde les voyants s éteindront et l un d eux clignotera brièvement o Si le voyant System clignote tous les contrôles de santé de la carte sont passés o Si le voyant LoRa clignote l un des contrôles d intégrité ...

Page 27: ...ona All in One Home Sensor User Guide T0005370_UG Version 0 4 TEKTELIC Communications Inc Confidential Page 28 of 32 Le voyant System peut être contrôlé via l interface de commande de liaison descendante ...

Page 28: ...y modèle CR2450 FDK Corporation modèle CR2450 Pour accéder à la batterie les deux vis de fixation du boîtier doivent être retirées Les vis sont accessibles sur le fond du boîtier du capteur et nécessitent un tournevis Torx T 3 Ouverture du boîtier Retirez les deux vis T 3 sur le fond du boîtier Tout en maintenant le capteur avec la partie inférieure vers le haut retirez le bas du boîtier Avec le f...

Page 29: ...e bouton est marqué d un symbole indiquant la borne positive Ce terminal positif doit être orienté vers le haut lors du remplacement de la cellule Poussez l autre extrémité de la cellule dans le support jusqu à ce qu elle se clipse positivement dans le support Lors de la réinsertion de la batterie assurez vous que les crochets métalliques du support de la batterie sont au dessus de la batterie ava...

Page 30: ...menté pour obtenir de l aide Pour respecter les limites d exposition RF FCC IC pour la population générale exposition incontrôlée les antennes utilisées pour cet émetteur doivent être installées de manière à fournir une distance de séparation d au moins 20 cm par rapport à toutes les personnes et ne doivent pas être co localisées toute autre antenne ou émetteur Ce produit doit être installé par de...

Page 31: ......

Reviews: