background image

Rev

.

 9-v3_7_en

 

 

Step-4

а     

Installation on the wall 

(NO BRACKET)

 

Step-4b 

Installation in the corner 

(WITH BRACKET) 

 

 

Step-5

а

  

Make  marking  on  the  wall 
at 

the 

required 

height 

applying 

the 

base 

to 

installation surface. 

 

Detector  base  should  be 
positioned  strictly  as  per 
figure of the step 4a  

 

 

Step-5b   

Mount  and  fix  the 

bracket at a required height 

 

 

 

Step-6

а 

Lead  wires  from  power 
supply 

source 

and 

signaling  zones  through 
wire  insertion  hole  on  the 
base. 

 

Attach  the  base  to  the 
wall

 

Step-6b   

Mount the base 

on  the  bracket  by  inserting 
bracket  latches  into  the  de-
tector base slot.

  

Detector  base  should  be 

positioned  strictly  as  per 
figure of the step 4a. 

 

Lead 

wires 

from 

power 

supply  source  and  signaling 
zones  through  wire  insertion 
hole on the base

 

Step-7

  

Depending  on  a  selected 
PCB  position,  set  the  ec-
centric  knob  up  or  down 
by  rotating  the  eccentric 
around its axis

  

 

 

Step-8 

 
Replace PCB on its 
place, superposing PCB 
hole with the eccentric 
knob 

 

 

Step-9    

Connect wires to detector 
terminals 
 

 

Step-10   

Using  sealing  material  of  distribution  kit  seal 

hermetically  wire  insertion  hole  and  other  holes  to  protect 
detector from air and insects ingress

 

Step-11 

Remove jumper from the 

Mem

 

plug.

 

Install jumpers on 

Sens 

and

 Ind 

plugs

 

 

   

 
 
 

 

 

 
 
 

 

 

Step-12   

Turn the detector ON; the indicator blinks 

once 

per 1 s

 for no longer than 60 s 

– it means the detector is be-

ing switched to the operating mode 

Step-13

      

During  starting  of  detector  operating 
mode  remove  for  a  short  period  of 
time (2-3s) and install back jumper of 

Ind 

plug

 

(

TEST-pass

 mode switches 

on for 8min) 

 

 

 

Step-14

 

 

Install  detector  cover  on  its 
place (until the click) 

 

 

 

 

Step-15  

To  detect  sensitive  zones  carry 
out 

TEST-pass 

  in  the  secured 

zone with the speed of 

0,3 

m/s.  

On  detection  (indicator  is  lighted 
for  2s)  one  should  stop,  mark  this 
position, then make step back and 
continue moving.  

 

 

Repeat 

TEST-pass

 in the opposite direction. 

Sensitive  areas  formed  by  lens  will  be  in  the  middle  of  the 
marked positions.

 

Step-16 

 

Push out cover lock from base 
slot.  
Remove cover

 

 

 

 

 

 

 

 

Press out 
blanks of 
selected 
mounting 
holes 

Press out 
blank of 
bracket 
mounting slot  

Mounting 

holes 

Bracket 

latches 

Summary of Contents for Astra-9

Page 1: ...0 in the upper PCB position 7 7 Movement speed detection range m s from 0 3 up to 3 0 Resistance to ambient light lx min 6500 Recommended installation height m from 2 4 up to 2 5 General Technical Parameters Power supply voltage V from 8 up to 15 Current consumption in standby mode and in Alarm mode mA max 15 Relay contacts permissible current mА max 0 08 Relay contacts permissible voltage V max 1...

Page 2: ...otected area To switch the mode OFF and reset indication remove jumper from Mem plug or switch power OFF TEST pass allows revealing precise location of sensitive zones formed by the lens On expiry of 8 min the detector automatically starts its stand by mode 8 Installation and Pre starting Procedure 8 1 Works on installation mounting maintenance and operation of detector should be performed by only...

Page 3: ... wires to detector terminals Step 10 Using sealing material of distribution kit seal hermetically wire insertion hole and other holes to protect detector from air and insects ingress Step 11 Remove jumper from the Mem plug Install jumpers on Sens and Ind plugs Step 12 Turn the detector ON the indicator blinks once per 1 s for no longer than 60 s it means the detector is be ing switched to the oper...

Page 4: ...n tech nology equipment 11 Recycling The detector does not pose any life or health risk to individuals or to the environment Once its service life is complete the detector may be utilized with no special environment protection measures 12 Manufacturer Warranties 12 1 Quality Management System meets provisions of ISO 9001 2011 12 2 The manufacturer guarantees the compliance of the de tector with te...