5.1.3 - RF Setting
In the RF part, our frequency is automatically loaded to the selected channels, we do not
need to change.
Our maximum value of 100 in the power section corresponds to 107.8 dBuV in our receiver.
Our minimum value of 0 allows us to see 82.3 dBuV.
The next 4 frequencies are automatically assigned according to the entered frequency.
For example, entering 306 MHz will automatically assign 314MHz-322MHz-330MHz.
5.1.4 - IP SETTING
You can see the IP address of our device in the System > LAN section and changes can be
made upon request.
The IP value to be given when changing the IP must be in base 1.