United Kingdom Type Gas Connection:
WARNING:
The gas hose must not be clamped, bent ar trapped or come
into contact with hat parts of the product. There is the risk of explosion
due to damaged gas hose.
Ventilation Of Room
The air needed for burning is received from room air and the gases
emitted are given directly in room. For safe operation of your product,
good room ventilation is a precondition. If no window or room to be
utilized for room ventilation is available, additional ventilation should
be installed. However, room has a door opening outside, it is no needed
to vent holes.
Room Size
Ventilating Opening
Smaller than 5m³
min. 100cm²
Between 5m³ - 10m³
min. 50cm²
Bigger than 10m³
no need
In basement or cellar
min. 65cm²
77l
6
5
/
r
4
F
rn
2
c, __ _
1. Gasket
2. Adapter
3. Gas (safety) hose
4. Valve with 90
°
outlet
5. Connection piece