background image

 

 

 
 
 
 

Operating instructions 

 

 

Type 

 

TEKA–LMD 508 

 

 
 
 
 
 
 
 
 

TEKA 

Absaug- und Entsorgungs- 

technologie GmbH 

Industriestraße 13   D-46342 Velen 
Postfach 1137   D-46334 Velen 

Tel.: +49 (0) 2863 9282-0 
Fax: +49 (0) 2863 9282-72 

E-Mail: 

[email protected]

 

www.teka.eu

 

Summary of Contents for LMD 508

Page 1: ...nstructions Type TEKA LMD 508 TEKA Absaug und Entsorgungs technologie GmbH Industriestra e 13 D 46342 Velen Postfach 1137 D 46334 Velen Tel 49 0 2863 9282 0 Fax 49 0 2863 9282 72 E Mail sales teka eu...

Page 2: ...mmissioning 6 5 1 Attaching the extractor fittings 6 5 2 Electrical connection of the unit 7 6 Operation of the system 8 7 Maintenance 8 7 1 Replacing the prefilter matting 9 7 2 Replacing the particl...

Page 3: ...Filter door Ventilator housing Ventilator door Castor Castor with brake Twist lock fastener Lifting mechanism Pos 11 Pos 13 Pos 14 Pos 15 Pos 16 Pos 17 Pos 18 Pos 19 Locking screw for the lifting mec...

Page 4: ...complete volume of air in the workshop is replaced However this method only achieves a small reduction in the level of pollution within the breathing space of the user The same applies to the so call...

Page 5: ...to the point where the suction force decreases the filter must be replaced because it is clogged with the extracted dust and smoke particles see Section 7 1 Replacing the prefilter matting Section 7...

Page 6: ...possible damage The unit must not be used if the mains supply cable is not in perfect condition Do not use the filter unit if one or more of its components are faulty missing or damaged In any of the...

Page 7: ...e motor speed of the turbine 3 4 Filter alarm Floating output normal open contact for interpretation of the warn alarm Filter alarm 5 6 Operation control Floating output normal open contact for interp...

Page 8: ...ce decreases the particle filter Pos 14 must be replaced because it is clogged with the extracted dust and smoke particles see Section 7 2 Replacing the particle filter The activated carbon cassette P...

Page 9: ...14 Use the fixing screw Pos 11 to raise the lifting mechanism Pos 10 so that the particle filter Pos 14 fits tightly underneath the equipment cover Pos 2 Close the filter door Pos 4 Connect the filte...

Page 10: ...activated carbon cassettes Use the fixing screw Pos 11 to raise the lifting mechanism Pos 10 so that the particle filter Pos 14 fits tightly underneath the equipment cover Pos 2 Close the filter door...

Page 11: ...e Ph 1 Frequency Hz 50 Motor power kW 1 2 Max airflow volume m h 320 Max partial vacuum Pa 21000 Enclosure type IP 54 ISO class F Operating voltage V 230 Duty cycle 100 Width x depth x height mm 365 x...

Page 12: ...article filter Pos 14 Activated carbon cassette Pos 15 Activated carbon pouring Turbine 1 2kW with elektronic Castor Pos 11 Castor with brake Pos 12 Suction hose length 2 5m NW45 with air intake Sucti...

Page 13: ...ng directives Machinery directive 2006 42 EG Electromagnetic compatibility 2014 30 EU Pressure equipment device 97 23 EG Low voltage directive 2006 95 EG Applied harmonised standards DIN EN 349 DIN EN...