![Teka IR 630 Installation Instructions And Recommendations For Use And Maintenance Download Page 16](http://html1.mh-extra.com/html/teka/ir-630/ir-630_installation-instructions-and-recommendations-for-use-and-maintenance_1075743016.webp)
GB
16
When the "safety disconnecting" has occu-
rred, in the corresponding plate's power
indicator the residual heat
H
indicator will
be displayed, if the glass temperature is
high enough.
SAFETY WHEN SENSORS ARE COVE-
RED
The Touch Control incorporates a function
that detects when any object (container,
cloth or certain liquids) are covering the
panel sensors for more than 10 seconds.
This is to avoid the object activating or
deactivating any of the plates without you
realizing.
When the Touch Control detects an object
covering the sensors, it starts to bleep until
the object covering the control panel is
removed. If the Touch Control was turned
on, it is automatically disconnected for
safety reasons.
If after a few minutes the object covering
the sensors is not removed, the bleeping
will stop.
Take into account that this safety
function is activated even though the
Touch Control is turned off!
Do not leave any objects down on
the Touch Control!
Clock
(except models …630)
The top is fitted with a clock that can be
used for two different functions: as a plate
timer or as a countdown chronometer.
The clock as a countdown timer
(except models …630)
With this function, you can set a time after
which a sound signal will be heard.
To activate this function, proceed as
follows:
1
With the Touch Control powered on and
no plate with the timer activated, touch
one of the sensors
(11) or
(12)
corresponding to the clock.
2
Power on the indicator (7), displaying
00
.
3
Touch the sensors
(11) or
(12)
again to set the required time. After a
few seconds, the decimal point on clock
will start to blink (13), indicating that the
countdown has begun.
Be careful not to touch different sensors
other than
(11) or
(12) since, by
doing so, a plate may cease timing instead
of programming the chronometer.
Once the countdown has reached zero, a
series of bleeps will be heard. These can
be cancelled by touching any of the sen-
sors
(11) or
(12) associated with
Table 2
8
8
5
4
4
3
3
2
2
1
10 minutes
1
2
3
4
5
6
7
8
9
P
Power
selected
MAXIMUM
OPERATION TIME