background image

Maintenance MXSE

TECHNICAL INFORMATION
Soap viscosity: 1-3000 MPas
Tank size: 0,8 L
Battery: 4 pcs Alkaline 1,5V AA batteries (not
included)
Battery life time: 10.000 cycles or 1 year.
Soap consumption per cycle: 0,034 - 0,051 ml
Delay: 500-1k msec
Functional area for sensor: 60±38 mm
Operative room temperature: 5-40°C
Operating motde: Starts automatically when
triggering sensorType of pump: Self-contained valve
ozzle

MAINTENANCE OF SOAP DISPENSER
The soap container must be cleaned before every
refill- Ensure that there is no solidified soap on the
spout, the sensor, on the lid of the soap tank and that
the vent hole in the lid is open. the control unit must
never be washed under running water or immersed
in water. Use a damp cloth for cleaning.

DIAGNOSIS OF BATTERY
Open the dispenser and remove the soap tank from
the controller.
1. Press on the little blue button under the control unit
and hold it.
2. Observe the LED indicator light. 3-4 blinks indicate
battery capacity
3. If the Led indicator light continues to blink, it's time
to replace the batteries. Replace all batteries at the
same time.
 

TROUBLESHOOTING
IT DOES NOT COME OUT SOAP:

a) Check if it is solidified soap or other dirt on the
spout and sensor plate. Wash well to make it clean.
b) Check the soap in the container. Refill if necessary.
c) Check the batteries.
d) Check soap quality and that this is within the
requirements of applicable soap. Clen the container
and fill with the correct soap.
e) Check that the spout of the dispenser is in tension
in the control unit. Romove and place again if this is
not the case.
f) Check that there are no reflections that confuse the
sensor. Remove this if necessary-
g) Check that the protection of the spout is removed
(after installation).
Battery LED indicator is not blinking:
The cover of the dispenser must be open for the LED
indicator to appear. Replace battery.
Battery LED indicator is blinking continually:
If the led indicator does not stop blinking after 3-4
flashes, it is time to change the batteries. Replace all
at once.
It comes to small dose of soap:
Remove the soap container and wash container,
spout and lid. Ensure that the hole in the lid is open
and also that the spout is open. Then fill the container
with new soap of the right quality before the
container is repositioned. Check tha the spout is in
tension and tighten between the upper and lower part
of the control unit and that the spring-loaded door is
closed.
It is leaking soap from the bottom of the dispenser:
Check if there is a hole/crack in the soap container or
pipe to the spout. Replace tank if necessary

4

FDV Revision 20160217

www.intra-teka.com

Reviews: