INSTALLATION
TECHNICAL INFORMATION FOR THE INSTALLER
Installation, adjustments of controls and
maintenance must only be carried out by a qualified
engineer.
Incorrect installation may cause damage to persons,
animals or property for which the Manufacturer shall
not be considered responsible.
During the life of the system, the automatic safety or
regulating devices on the appliance may only be
modified by the manufacturer or by his duly
authorized dealer.
3) INSTALLING THE HOT PLATE
Check that the appliance is in a good condition after
having removed the outer packaging and internal
wrappings from around the various loose parts. In case
of doubt, do not use the appliance and contact qualified
personnel.
Never leave the packaging materials (cardboard,
bags, polystyrene foam, nails, etc.) within children’s
reach since they could become potential sources of
danger.
The measurements of the opening made in the top of the
modular cabinet and into which the hot plate will be
installed are indicated in either fig. 7. Always comply with
the measurements given for the hole into which the
appliance will be recessed (see fig. 7 and 8).
The appliance belongs to class 3 and is therefore
subject to all the provisions established by the
provisions governing such appliances.
3A) CYLINDER HOLDER COMPARTMENT
The dimensions of the cylinder compartment have to
permit the easy loading and unloading of the cylinder.
For an efficient aeration is necessary to make some
small openings in the furniture, as per fig. 9/A and 9/B.
The cylinder holder compartment must have the
following characteristics:
- resistance to a load.
- No fitment of the cylinder directly on the floor are
allowed.
- The cylinder equipped with governor must be set or
take off from the compartment in a easy way.
- The cylinder cock must be easily accessible.
- The flexible tube musn't be in contact with sharp
edges.
- The cylinder holder compartment and the different
parts of the unit, where the burners are fit, musn't be in
touch inside.
- The aeration openings musn't be occluded when the