12
BURNER ARRANGEMENT ON THE HOT PLATE
OTHERS MARKETS
CONVERSIONS
12) REPLACING THE INJECTORS
The burners can be adapted to different types of gas
by installing injectors suited to the type of gas
required. To do this, first remove the burner tops
using a wrench “B”. Now unscrew injector “A” (see
fig. 15) and fit a injector corresponding to the type of
gas required.
It is advisable to tighten the injector in place.
After the injectors have been replaced, the burners must
be regulated as explained in paragraphs 11. The
technician must reset any seals on the regulating or pre-
regulating devices and affix the label corresponding to
the new gas regulation on the appliance instead of the
already existing one. This label is supplied in the packet
containing the spare injectors.
The envelope with the injectors and the labels can be
included in the kit, or at disposal to the authorized
customer Service Centre.
For the sake of convenience, the nominal rate chart also lists
the heat inputs of the burners, the diameter of the injectors
and the working pressures of the various types of gas.
G30 - BUTANE
28 - 30
225
90
1400
3100 62
G31 - PROPANE
37
222
90
1400
3100 62
G20 - NATURAL
20
295
121 Y
1400
3100 Adj.
G30 - BUTANE
28 - 30
204
83
800
2800 45
G31 - PROPANE
37
200
83
800
2800 45
G20 - NATURAL
20
267
117 S
800
2800 Adj.
G30 - BUTANE
28 - 30
127
65
500
1750 35
G31 - PROPANE
37
125
65
500
1750 35
G20 - NATURAL
20
167
97 Z
500
1750 Adj.
BURNERS
N°
DESCRIPTION
GAS
NORMAL
PRESSURE
NORMAL
RATE
INJECTOR
DIAMETER
NOMINAL HEAT
INPUT (W)
mbar
g/h
l/h
1/100 mm
MIN.
MAX. 1/100 mm
1
ULTRA RAPID
2
RAPID
3
SEMIRAPID
BY
PASS
4
AUXILIARY
G30 - BUTANE
28 - 30
73
50
400
1000 30
G31 - PROPANE
37
71
50
400
1000 30
G20 - NATURAL
20
95
72 X
400
1000 Adj.
5
FISH
G30 - BUTANE
28 - 30
204
83
1400
2800
62
G31 - PROPANE
37
200
83
1400
2800
62
G20 - NATURAL
20
267
117 S
1400
2800
Adj.
FIG. 15