8) ELECTRICAL CONNECTION
The electrical connections of the appliance
must be carried out in compliance with the
provisions and standards in force.
Before connecting the appliance, check that:
- the electrical capacity of the mains supply and
current sockets suit the maximum power rating of
the appliance (consult the data label applied to the
underside of the hot plate).
- The socket or system has an efficient earth
connection in compliance with the provisions and
standards in force. The manufacturer declines all
responsibility for failing to comply with these
provisions.
When the appliance is connected to the
electricity main by a socket:
- fit a standard plug suited to the load indicated on
the data label to the cable (see fig. 12).
- Fit the wires following figure n. 12, taking care of
respecting the following correspondences:
letter L (live) = brown wire;
letter N (neutral) = blue wire;
earth symbol
= green - yellow wire.
- The power supply cable must be positioned so
that no part of it is able to reach an
overtemperature of 75 K.
- Never use reductions, adapters of shunts for
connection since these could create false contacts
and lead to dangerous overheating.
- The outlet must be accessible after the built-in.
When the appliance is connected straight to the
electricity main:
- install an omnipolar circuit-breaker between the
appliance and the electricity main. This circuit-
breaker should be sized according to the load
rating of the appliance and possess a minimum 3
mm gap between its contacts.
- Remember that the earth wire must not be
interrupted by the circuit-breaker.
- Alternatively, the electrical connection may also be
protected by a high sensitivity differential circuit-
breaker.
You are strongly advised to fix the relative yellow-
green earth wire to an efficient earthing system.
WARNINGS:
the rear wall, adjacent and surrounding
surfaces must therefore be able to withstand
an overtemperature of 65 K.
all our appliances are designed and
manufactured in compliance with European
standards EN 60 335-1, EN 60 335-2-6 and
EN 60 335-2-102 plus the relative amendments.
The appliance complies with the provisions of
the following CEE Directives:
- CEE 2004/108/CE regarding to electromagnetic
compatibility.
- CEE 2006/95 regarding electrical safety.
INSTALLATION
FIG. 12
Summary of Contents for EWF 60 4G AI AL CI
Page 7: ...7 INSTALACI N...
Page 9: ...9 INSTALACI N INSTALACI N DE PLACA SEMIFILO FIG 11 A FIG 11 B...
Page 17: ...DATOS T CNICOS DE LA REGULACI N DEL GAS DEL EQUIPO 17...
Page 25: ...25 INSTALLATION...
Page 27: ...27 INSTALLATION SEMIFILO HOT PLATE INSTALLATION FIG 11 A FIG 11 B...
Page 35: ...35 TECHNICAL DATA FOR THE APPLIANCE GAS REGULATION...
Page 43: ...43 INSTALLATION...
Page 45: ...45 INSTALLATION INSTALLATION DE CUISSON OU GAZ SEMIFILO FIG 11 A FIG 11 B...
Page 53: ...53 DONNEES TECHNIQUES DE LA R GULATION GAZ DE L APPAREIL...
Page 58: ...58 h 3 4 5 EIK 3 EIK 4 EIK 5 5 6...
Page 59: ...59 2 C T 6 spray o n T 6 C 6 EIK 6...
Page 61: ...61...
Page 62: ...62 FILOTOP 565 495 65 590 520 R 14 R 14 5 521 591 3 3 EIK 10 A 65 3 3 EIK 10 B...
Page 63: ...63 SEMIFILO EIK 11 A EIK 11 B...
Page 66: ...66 EIK 13 9 1 M 13 D C 13 G20 G30 G31...
Page 68: ...68 EIK 18 EIK 19 EIK 15 EIK 16 EIK 17 11 V 15 16 17 18 D 19...
Page 69: ...69 EIK 20 20 8 H05 RR F 3 x 0 75 mm2...
Page 71: ...71...
Page 72: ...72...