FIG. 12
REGULATION AND TRANSFORMATION OPERATIONS
10) REPLACING NOZZLES
The burners can be adapted to suited different
types of gas by fitting the nozzles that correspond to
the gas used. To do this, it is necessary to remove
the burner heads and use a straight key “B”, to
unscrew the nozzle “A” (see fig. 12) and replace it
with a nozzle corresponding to the gas used.
We advise you to block the nozzle tightly.
After making these replacements, the technician
must regulate the burners as described in
paragraph 9, seal any regulation or pre-
regulation organs and apply the label
corresponding to the new gas regulation carried
out on the appliance in place of that previously
applied. This label is contained in the spare
nozzle bag.
For the ease of the fitter, we have prepared a table
indicating the flow capacities, the heat capacities of
the burners, the diameter of the nozzles and the
working pressure for the various types of gas.
ARRANGEMENT OF THE BURNERS
TABLE
BURNERS
TYPE OF GAS
WORKING
PRESSURE
mbar
HEAT
CAPACITY
NOZZLE
DIAMETER
1/100 mm
HEAT
CAPACITY (W)
No.
DENOMINATION
g/h
l/h
Min. Max.
1
DOUBLE RING
G 30 - BUTANE
G 31 - PROPANE
G 20 - NATURAL
28-30
37
20
298
293
390
2 x 69 A + 46 B
2 x 69 A + 46 B
2 x 110 A + 71 A
1800
1800
1800
4100
4100
4100
2
RAPID
G 30 - BUTANE
G 31 - PROPANE
G 20 - NATURAL
28-30
37
20
204
200
267
83
83
117 Y
800
800
800
2800
2800
2800
3
SEMIRAPID
REDUCED
G 30 - BUTANE
G 31 - PROPANE
G 20 - NATURAL
28-30
37
20
98
96
133
58
58
85 Y
650
650
600
1350
1350
1400
4
SEMIRAPID
G 30 - BUTANE
G 31 - PROPANE
G 20 - NATURAL
28-30
37
20
127
125
167
65
65
98 Z
650
650
600
1750
1750
1750
5
AUXILIARY
G 30 - BUTANE
G 31 - PROPANE
G 20 - NATURAL
28-30
37
20
73
71
95
50
50
75 X
550
550
450
1000
1000
1000
40
Summary of Contents for CGW LUX 60 TC 4G AI AL CI
Page 18: ...REGULACIÓNYTRANSFORMACIÓN OPERACIONES MEDIDAS tarjeta electrónica agujeros 18 ...
Page 23: ...DATOS TÉCNICOS DE LA REGULACIÓN DEL GAS DEL EQUIPO 23 ...
Page 42: ...REGULATION AND TRANSFORMATION OPERATIONS MEASUREMENTS electronic card 42 holes ...
Page 47: ...TECHNICAL DATA OF THE APPLIANCE GAS REGULATION 47 ...
Page 65: ...65 OPÉRATIONS DE RÉGLAGE ET DE TRANSFORMATION MESURES carte électronique trous ...
Page 87: ... ΙΑΣΤΑΣΕΙΣ ηλεκτρονική κάρτα τρύπες ΜΕΤΑΤΡΟΠΕΣ 87 ...
Page 110: ...110 MEDIDAS placa electrónica REGULAÇÕES buracos ...
Page 116: ...116 ...