BA_Airfilter Mini_151210_GB.doc
- 15 -
22.07.2013
7 Maintenance
7.1 General information
All service work must be carried out within the given deadlines and with the corresponding
care.
The life and production quality of the Airfilter can be maintained through precautionary service
of the components.
Besides the regular cleaning you are urgently advised to replace parts subject to wear and
tear as a precautionary measure.
7.2 Replacement of the combifilter
The filter elements are to be replaced, as soon as the measured pressure differential on the
combifilter exceeds the set end value. The display of the pressure differential in the transpar-
ent display shows in this case 100 % and the red error LED (Error) will light permanently.
Some Airfilter models have also been equipped with an acoustic signal (acoustic alarm), that
gives a clear beep sound to report that the filter needs to be replaced.
Note!
The acoustic signal installed in several Airfilter models can be switched off by pressing one of
the b, – or ENTER on the membrane keyboard once.
The acoustic alarm will sound once again every time the Airfilter is switched on.
So that you are regularly reminded that the combifilter needs to be replaced in permanent
operation of the Airfilter, the acoustic signal will be repeated after 8 hours, then after 4 hours,
after 2 hours and then each further hour.
The alarm will cease to sound immediately only after the combifilter has been replaced.
Caution!
Poisonous dust!
When working with /on the filter elements there is the danger that you may breath in raised
dust or come into contact with such.
●
Therefore, before commencement of the work you should put on a fine dust mask of the
protective level 3 and disposal gloves made of polyethylene (long design).
You should proceed as follows when replacing the filter: