5.3. Installing the automatic cleaning mechanism
This section is only relevant if the system is equipped with the optional automatic cleaning
mechanism.
●
Release the toggle levers (see section 2.1) and remove the turbine housing.
●
Place the cleaning mechanism housing on the filter housing (see section 2.1). When you do
this, the outlet hole (A) must face downwards.
●
Place the turbine housing on the cleaning mechanism housing.
●
Fix the housing in place using the toggle levers. When you do this, you should also use the long
locking hooks supplied (B) in order to compensate for any height differences.
●
Connect the supplied control cable to the clock generator (C) and the interface (D).