background image

 

 

seconds. This setting is stored to internal flash memory, and remains if power is 
removed. 

Right mode and Left mode:

  While locked, holding the 

Fire 

and 

UP  

buttons 

simultaneously for 5 seconds flips the display. This allows for accommodating to 
left or right handed use. This setting is stored to internal flash memory, and 
remains if power is removed. 

Power Locked mode:

 Holding down both the 

UP 

and

 DOWN 

buttons for 2 seconds 

will place the device in Power Locked mode. In this mode, the mod will operate 
normally, but you will not be able to change to power setting. This mode prevents 
accidental power level change due to the buttons being pressed while in a pocket. 
To exit Power Locked mode, hold 

UP 

and 

DOWN 

buttons for 2 seconds. 

Maximum Temperature Adjust:

  From Locked mode, holding down both the 

UP 

and 

DOWN 

buttons for 2 seconds will place the device in Max Temperature 

Adjust mode. Once this mode is entered, the max temperature will be displayed. 
The 

UP 

and 

DOWN 

buttons are used to adjust the max temperature. To save the 

new temperature setting and exit, press the 

Fire

 button. 

 

Error Messages: 

The Dna 40 will indicate a variety of error states. 

Check Atomizer:  

The Dna 40  does not detect an atomizer, the atomizer has 

shorted out, or the atomizer resistance is incorrect for the power setting. 

Shorted:

  The atomizer or wiring are shorted circuited. 

Weak Battery:

  The battery needs to be charged, or a higher rate battery needs to 

be used. If this happens, the Dna 40 will continue to fire the atomizer, but will not 
be able to provide the desired wattage. The 

Weak Battery

 message will continue 

to flash for few seconds after end of puff. 

Temperature protection:

  The heating coil reached the maximum allowed 

temperature during the puff. If this happens, the Dna 40 will continue to fire, but 
will not be able to provide the desired wattage. 

Summary of Contents for Minion 2.0

Page 1: ...TEKDIVISION S R O MinioN 2 0 Personal vaporizer User manual...

Page 2: ...aintenance The body of the Minion box mod is made of non corrosive aluminium alloy Doesn t need special treatment however avoid contact whit aggressive liquids like corrosive house hold cleaners antic...

Page 3: ...2 NEGATIVE BATTERY CONTACT SCREW unfasten the screw till you will be able to pull the top cap 3 ATOMIZER 510 CONECTION 4 FIRE BUTTON 5 HEX SCREW FOR 510 CONECTION ROTATING ADJUSTMENT 6 DOWN BUTTON...

Page 4: ...1 microUSB CHARGING PORT 2 DNA40 DISPLAY 3 WARRANTY SEALING 4 CHARGING INDICATORS RED charging in progress BLUE charging completed...

Page 5: ...l Chromium or Kanthal alloys Nickel 200 is commercially pure nickel It is often sold in vapor shops and online as non resistance wire If the temperature reaches the maximum value the wattage applied t...

Page 6: ...ture will be displayed and the UP and Down buttons should be released 4 Use the UP and Down buttons to adjust the maximum temperature 5 When the display shows the desired maximum temperature press the...

Page 7: ...40 will prompt you to confirm this change When you fire the first time before activating the Dna 40 will prompt New Coil UP YES DOWN NO When you see this prompt if you have attached a new atomizer pr...

Page 8: ...being supplied to the atomizer Ohms display The resistance of atomizer attached to the device This is measured only when the unit is supplying power to the atomizer At other times it shows the most r...

Page 9: ...for 2 seconds will place the device in Max Temperature Adjust mode Once this mode is entered the max temperature will be displayed The UP and DOWN buttons are used to adjust the max temperature To sa...

Page 10: ...s the Dna 40 will continue to fire but will not be able to provide the desired wattage The Ohms Too Low message will continue to flash for a few seconds after the end of puff Too Hot The Dna 40 has on...

Reviews: