background image

 

 

Ohms Too High:

  The resistance of the atomizer coil is too high for the current 

wattage setting. If this happens, the Dna 40 will continue to fire, but will not be 
able to provide the desired wattage. The 

Ohms Too High

 message will continue to 

flash for a few seconds after the end of puff. 

Ohms Too Low:

  The resistance of the atomizer coil is too low for the current 

wattage setting. If this happens, the Dna 40 will continue to fire, but will not be 
able to provide the desired wattage. The 

Ohms Too Low

 message will continue to 

flash for a few seconds after the end of puff. 

Too Hot:

  The Dna 40 has onboard temperature sensing. It will shut down and 

display this message if the internal board temperature becomes excessive. 

 

Auto power down: 

The screen will be at full brightness while firing. After 10 seconds with no button 
presses, the screen will dim. 30seconds after the last button press, the screen will 
fade out and the device will go into sleep mode. To wake the device, press the 

Fire

 button. 

 

 

 

Summary of Contents for Minion 2.0

Page 1: ...TEKDIVISION S R O MinioN 2 0 Personal vaporizer User manual...

Page 2: ...aintenance The body of the Minion box mod is made of non corrosive aluminium alloy Doesn t need special treatment however avoid contact whit aggressive liquids like corrosive house hold cleaners antic...

Page 3: ...2 NEGATIVE BATTERY CONTACT SCREW unfasten the screw till you will be able to pull the top cap 3 ATOMIZER 510 CONECTION 4 FIRE BUTTON 5 HEX SCREW FOR 510 CONECTION ROTATING ADJUSTMENT 6 DOWN BUTTON...

Page 4: ...1 microUSB CHARGING PORT 2 DNA40 DISPLAY 3 WARRANTY SEALING 4 CHARGING INDICATORS RED charging in progress BLUE charging completed...

Page 5: ...l Chromium or Kanthal alloys Nickel 200 is commercially pure nickel It is often sold in vapor shops and online as non resistance wire If the temperature reaches the maximum value the wattage applied t...

Page 6: ...ture will be displayed and the UP and Down buttons should be released 4 Use the UP and Down buttons to adjust the maximum temperature 5 When the display shows the desired maximum temperature press the...

Page 7: ...40 will prompt you to confirm this change When you fire the first time before activating the Dna 40 will prompt New Coil UP YES DOWN NO When you see this prompt if you have attached a new atomizer pr...

Page 8: ...being supplied to the atomizer Ohms display The resistance of atomizer attached to the device This is measured only when the unit is supplying power to the atomizer At other times it shows the most r...

Page 9: ...for 2 seconds will place the device in Max Temperature Adjust mode Once this mode is entered the max temperature will be displayed The UP and DOWN buttons are used to adjust the max temperature To sa...

Page 10: ...s the Dna 40 will continue to fire but will not be able to provide the desired wattage The Ohms Too Low message will continue to flash for a few seconds after the end of puff Too Hot The Dna 40 has on...

Reviews: