Over-current protection
If the maximum current is
higher than the limited, the
relay will be permanently
cut off, the red light will start
to flash, and it needs to be
manually powered back on.
Short circuit protection
The fuse is blown and then
the power supply is no
longer continued. A new
fuse needs to be manually
replaced to recharge it.
Low voltage protection
Under the minimum voltage
limit, the relay is cut off and
the red light flashes. After
the
normal
voltage
is
restored, manual power-on
can be restored.
Over voltage protection
Above the maximum limit
voltage, the relay is cut off
and the red light flashes.
After restoring the normal
voltage,
the
manual
power-on can be restored.
5.Installation Instructions
5.1 Tools list
Electric drill (self-prepared), tool hammer (self-prepared), marker (self-provided), Φ8
expansion screw, mounting bracket.
5.2 Installation Steps
a.Charging station inlet connection
It is recommended to use power cable no less than 5*6mm²
。
b. Installation and Fixation of Charging Station
1
Please confirm the installation location and mark it (using the bracket strip). The
center of the charging station is 45 inches from the ground at least.
2
Use the electric drill to align the position of the mark and make two holes with a
diameter of Φ8.