Status of
charging
4.Troubleshooting
Trouble
:
Screen display
:
Resolution
:
Leakage Protection
Stop charging immediately.
The relay is cut off and the
red light flashes. You need
to manually power it back
on
Over temperature protection
When the temperature is higher
than 85 °C, the charging will stop
automatically, the relay will be
disconnected, the red light will
start
to
flash,
when
the
temperature drops below 85 °C,
and the charging condition is
met, the relay will automatically
pick up and start charging.
When
the
temperature
is
between 75 ° C and 85 ° C, the
control box will automatically
lower one gear position. When
the temperature is lower than
75 ° C, the gear position will
automatically recover
Charging capacity
Charging status
Charging Time
Voltage /Current
Rated current