pg. 21
Ultrasonic cleaning equipment
Filnet B300 ultrasonic
problem solving guide
problem
possible cause
solution
look up
The resistance heaters do
not heat up
The correct temperature is
not reached
The temperature is notco-
rrectly displayed
Malfunction in some of the
machine’s elements
Poor cleaning results
Heating circuit fuses in
poor condition
Tank cover open
Temperature probe in poor
condition
Electrical connection in poor
condition
Use of chemicals that are
not recommended by TEINNOVA
The chemical ratio is lower than that
recommended by TEINNOVA.
Fault in the circuit board
Page 21
Page 15 and 16
Page 21
Page 14 and 23
Page 18
Page 18
Page 21
Contact the technical service at Tecai Innova
S.L.
Close the tank correctly
Contact the technical service at Tecai Innova
S.L.
Connect the machine to the mains electricity
correctly.
Use chemicals recommended by TEINNOVA
Use the chemical ratios recommended by
TEINNOVA.
Contact the technical service at Tecai Innova
S.L.