background image

 

© by WilTec Wildanger Technik GmbH 

 

Item 50982, 51192

 

Page 5 

 

http://www.WilTec.de

 

http://www.aoyue.eu

 

 

 

02 2022

-1

 

http://www.teichtip.de

 

 

Controller unit

 

 

The controller consists of hook, panel, touch buttons and fixed foot.

 

 

 

 

 

Switch function

 

After the power is switched on, touch “START-STOP,” control the pump switch.

 

 

 Attention:

 please cut off the power if you do no use the pump for a long time.

 

 

 

Adjust the gear level

 

 
 

Touch “DOWN” or “UP” to adjust pump gear. Consult the detailed performance data below:

 

 

50982 (CET-8000)

 

 

Power supply

 

Gear level

 

Power

 (W)

 

Flow rate

 (

h

)

 

Max. lifting head

 

(m)

 

220–240

 

V, 50

 

Hz

 

SP01

 

18

 

3500

 

1.6

 

SP02

 

23

 

4000

 

1.9

 

SP03

 

28

 

4600

 

2.3

 

SP04

 

35

 

5000

 

2.7

 

SP05

 

42

 

5400

 

0.1

 

SP06

 

51

 

5800

 

3.5

 

SP07

 

60

 

6200

 

3.9

 

SP08

 

66

 

6700

 

4.5

 

Start
Stop

Summary of Contents for SUNSUN Adjustable SuperECO CET-15000

Page 1: ...llow the operating instructions and safety information before using for the first time Technical changes reserved Due to further developments illustrations functioning steps and technical data can dif...

Page 2: ...service wiltec info or use our contact form https www wiltec de contacts The most recent version of this manual in various languages can be found in our online shop via https www wiltec de docsearch...

Page 3: ...ct with heat or grease it must not touch sharp angles The pump may not be operated if the cable or the casing are defective Never transport any liquids other than water Attention The pump will automat...

Page 4: ...ems Installation 1 Notify your dealer immediately if there are external damages 2 Compare the voltage and frequency of your electrical circuit with the data on the model plate these data must correspo...

Page 5: ...ch START STOP control the pump switch Attention please cut off the power if you do no use the pump for a long time Adjust the gear level Touch DOWN or UP to adjust pump gear Consult the detailed perfo...

Page 6: ...With the correct gear you need to press down until the buzzer sounds twice The pump is now locked To unlock proceed in the same way Automatic memory function When the controller power is cut off sudde...

Page 7: ...ervoltage display Abnormal Check voltage Maintenance cleaning Please clean the filter casing impeller rotor and shaft part regularly Please cut off the power before you clean it 1 Turn and take off th...

Page 8: ...h the controller unit Re link to the controller unit The controller is damaged Change the controller Pump noise Dirt inside Clean pump Shaft break or wear Change shaft Pump water short age Damage of t...

Page 9: ...r European countries with a separate col lection system for these appliances The logo on the article or on its packaging points out that this article must not be treated as normal house hold waste but...