background image

e) Connect the charger only to a socket with an earth. Ensure that the mains voltage matches the 
specifications on the charger rating plate. Risk of electric shock.
f) Disconnect the charger from the mains before closing or opening connection to the battery / 
power tool / device.
g) Keep the charger clean and away from wet and rain. Do not use the charger outdoors. Dirt and 
the entry of water increase the risk of electric shock.
h) Operate the charger only with the appropriate original batteries. Charging other batteries may 
result in injuries and risk of fire.
I) Avoid mechanical damage to the charger. This can result in internal short circuits.
j) Do not operate the charger on a combustible surface (e.g. paper, textiles). Risk of fire due to 
heating during charging.
k) If the power cable for this equipment is damaged, it must be replaced by the manufacturer, a 
customer service agent of the same or a similarly qualified person in order to prevent hazards.
l) The battery of the appliance is not fully charged at the time of delivery. It therefore needs to be 
fully recharged before you use it for the first time. For the first recharge cycle we recommend that 
you charge the battery for about 1 hour. Slot the battery into the base and plug the battery charger 
into a mains outlet.
m) When the battery is fully charged, unplug the charger from the mains and from the appliance. 
Charging time is approx. 1
hour.
n) Do not charge the battery continuously since this may damage the battery cells.
Note: Repeatedly charging small capacities may damage the battery cells. Recharge the battery 
only if the appliance is becoming slow.
o) Do not use the charger to charge non-rechargeable batteries.

Even if properly operating and handling this electric tool, some residual risks will remain. Due to its 
construction and build, this electric tool may present the following hazards:

RESIDUAL RISKS

During operation, this electric tool generates an electromagnetic field which, under 
certain circumstances, may impair the functionality of active or passive medical 
implants. To reduce the risk of serious or lethal injuries, we recommend that persons 
with medical implants consult their doctor and the manufacturer of their medical 
implant before operating the machine.

WARNING

a) Cuts
b) Ear damage if working without ear protection.
c) Damage to your health caused by swinging your hands and arms when operating the appliance 
for longer periods of time or if the unit is not held or maintained properly.

1. Wait for the cutter to stop before setting the tool down. An exposed rotating cutter may engage 
the surface leading to possible loss of control and serious injury.
2. Use clamps or another practical way to secure and support the workpiece to a stable platform.
Holding the work by your hand or against the body leaves it unstable and may lead to loss of 
control.
3. Rags, cloth, cord, string and the like should never be left around the work area.
4. Avoid cutting nails. Inspect for and remove all nails from the workpiece before operation.
5. Use only sharp blades. Handle the blades very carefully.
6. Be sure the blade installation bolts are securely tightened before operation.
7. Hold the tool firmly with both hands.
8. Keep hands away from rotating parts.
9. Before using the tool on an actual workpiece, let it run for a while. Watch for vibration or 
wobbling that could indicate poor installation or a poorly balanced blade.

CORDLESS PLANER SAFETY WARNINGS

7

8

Summary of Contents for LP820

Page 1: ...Tools for Every Home Cordless Planer LP820 ...

Page 2: ...ton Battery On Off Switch Lock off Lever Depth Adjustor Model Rated Voltage Motor No Load Speed Planning Width Planning Depth Rabbeting Depth Compatible Battery LP820 DC 20V Brush 15000r min 82mm 0 2mm 0 10mm LB4 0Ah 1 2 ...

Page 3: ...h is in the off position before connecting to power source and or battery pack picking up or carrying the tool Carrying power tools with your finger on the switch or energizing power tools that have the switch on invites accidents d Remove any adjusting key or wrench before turning the power tool on A wrench or a key to a rotating part of the power tool may result in personal injury e Do not overr...

Page 4: ...ritation or burns a Ensure that the device is switched off before inserting the battery Inserting a battery into a power tool that is switched on may result in accidents b Recharge the batteries indoors only because the battery charger is designed for indoor use only c To reduce the electric shock hazard unplug the battery charger from the mains before cleaning the charger d Do not subject the bat...

Page 5: ... o Do not use the charger to charge non rechargeable batteries Even if properly operating and handling this electric tool some residual risks will remain Due to its construction and build this electric tool may present the following hazards RESIDUAL RISKS During operation this electric tool generates an electromagnetic field which under certain circumstances may impair the functionality of active ...

Page 6: ...ol WARNING INSTALLATION INSTRUCTION Always be sure that the tool is switched off and the battery cartridge is removed before carrying out any work on the tool WARNING REMOVING OR INSTALLING PLANER BLADES 1 Tighten the blade installation bolts carefully when attaching the blades to the tool A loose installation bolt can be dangerous Always check to see they are tightened securely 2 Handle the blade...

Page 7: ...Set the adjusting plate set plate on the gauge base so that the planer blade locating lugs on the set plate rest in the mini planer blade groove then press in the heel of the adjusting plate flush with the back side of the gauge base and tighten the pan head screws 4 It is important that the blade sits flush with the inside flank of the gauge plate the planer blade locating lugs sit in the blade g...

Page 8: ...ut half full remove the dust bag from the tool and pull the fastener out Empty the dust bag of its contents tapping it lightly so as to remove particles adhering to the insides which might hamper further collection 1 Fastener CONNECTING A VACUUM CLEANER For tool without nozzle When you wish to perform clean planing operation connect a vacuum cleaner to your tool Before connecting the vacuum cleane...

Page 9: ...ull the switch trigger Release the switch trigger to stop SWITCH ACTION 1 For your safety this tool is equipped with lock off lever which prevents the tool from unintended starting never use the tool if it runs when you simply pull the switch trigger without pressing the lock off lever Return tool a service center for proper repairs before further usage 2 Never tape down or defeat purpose and func...

Page 10: ...guide rule which is obtained as accessory PLANING OPERATION Hold the tool firmly with one hand on the knob and the other hand on the switch handle when performing the tool Draw a cutting line on the workpiece Insert the edge fence into the hole in the front of the tool Align the blade edge with the cutting line 1 Screw 2 Edge fence Adjust the edge fence until it comes in contact with the side of t...

Page 11: ...same time Use only identical carbon brushes REPLACING CARBON BRUSHES Use a screwdriver to remove the brush holder Take out the worm carbon brushes insert the new ones and secure the brush holder caps To maintain product SAFETY and RELIABILITY repairs any other maintenance or adjustment should be formed by TEH Authorized Service Centers always using TEH replacement parts Always keep your blades sha...

Page 12: ... Dear customers the warranty service for purchasing TEH products is as follows Under normal use within one year from the date of purchase It is guaranteed that the damage is caused by the quality of the tool The following conditions occur during the warranty period not covered by the warranty a Any valid legal document single ticket certifying the date of purchase b Any damage caused by natural we...

Reviews: