![TEGRAS Concept iFoam Mini User Manual Download Page 27](http://html1.mh-extra.com/html/tegras-concept/ifoam-mini/ifoam-mini_user-manual_1075459027.webp)
Intelligent active foam generator
27-30
o
problem solving guide
No foam is produced or
the quality is not good
enough
The machine does not
switch on
The fusebox short cir-
cuits
The passageway for liquids is clo-
sed in the lance handle
Page 18
Page 18 y 20
Page 9 y 20
-
Page 14
Page 14
Page 25
Page 14
Page 25
Page 25
Page 25
Squeeze the lance’s trigger
Hoses badly connected
Connect the hoses correctly
Foam
production mode does
not activate
Place the selector button on the foam produc-
tion function
Low levels of the chemical product
The equipment does not receive
power
Check that the chemical level in the Bag-in-
Box is correct.
Check the mains voltage
There is no mains water flow
Malfunctioning of the electrical
components in your equipment
Make sure that there is mains water input at
2 bar or greater
Contact the technical service at Tecai Innova
S.L.
Insufficient minimum pressure
from mains input
Incorrect dosage of the che-
mical
Make sure that there is mains water input at
2 bar or greater
Contact the technical service at Tecai Innova
S.L.
The internal pump does not work
The electrical shunt
Contact the technical service at Tecai Innova
S.L.
Contact the technical service at Tecai Innova
S.L.
problema
possible cause
solution
look up