9. OPERATINAL TEST

 

 

 

CHECKS IN TE EVENT OPERATIONAL FAILURE

 

In some situations, operational failure can arise due to simple causes that users themselves can solve, which is why prior to requesting the 

intervention of a specialised technician, we recommend that you carry out the following checks. 

The appliance does not work 

- Check that it is correctly plugged in. 

- Check that electricity reaches the power outlet. 
- Check that general switch is in the  

I/ON

 position. 

The internal temperature is too high 

-

Check that there is no heat source nearby. 

- Check that the grill is not obstructed. 

- Check the Set-point. 

- Check that the product loaded is perfectly distributed, without blocking the interior air ventilation exits and that the time elapsed since loading 

has been sufficient to chill the products. 

Check if the evaporator has ice. 

- Check that the condenser is not obstructed. 

- Check that the appliance is functioning normally.

 

In the event of strange or excessive noises 

- Check the levelling of the unit as this may cause vibrations. 

- Check that there is no object rubbing against any movable element of the refrigerated unit. 

 

 

 

NOISE TESTING

 

 

- The noise tests were performed in a room without any noise absorption elements and without any large item placed near to the refrigerated 

unit. 

- The noise levels registered in the acoustic test have been carried out in accordance with the ISO 230 to 235 standards. 

Leq

(continuous level) is less than 70 dB. (A) 

Lp

 (acoustic pressure level) is less than 130 dB. (C) 

 

NOTE. (A) (C) Frequency weights. 

 

 

 

10. DECOMMISSIONING 

Decommissioning 

 

The refrigerator cabinet containing polyurethane foam , oil, plastic parts , metal parts and electrical and electronic components. When the life of 

the furniture has come to an end and is necessary to remove the cabinet for destruction or partial recovery , the user is responsible  for 

delivering the product to the collection specified by the local authority for recovery and recycling WEEE professionals, always respecting the 

laws in force . The manufacturer is responsible for recovery, treatment and disposal at end of product life , in direct way or through a collective 

system make possible . If the rules are violated specific sanctions , established autonomously , according to the laws of each state belonging to 

the EC and conformally linked to all who are subject to those rules apply 

  Dismantling furniture 

 

In accordance with the rules on waste disposal in force in each country and full respect for the natural environment , we recommend subdividing 

the different parts of the furniture according to the material , separately or eliminate back. This product contains HFC ,ie , fluorinated gases with 

high value of greenhouse gas ( GWP). So: The component parts of the cooling circuit can not be cut or separated until the refrigerant gas has 

been extracted for recovery in a specialized center. 

 Declaration of conformity RoHS 

 

He declares under its own responsibility that the refrigerated cabinet to which this manual refers , meets the requirements of Directive 2002/95 / 

EC / (RoHS ) In all homogeneous materials used for manufacturing , the possible existence of lead, mercury , hexavalent chromium , 

polybrominated biphenyls (PBB ) and diphenyl ether (PBDE ) does not reach 0.01% by weight . This statement is based on statements of our 

suppliers of raw materials and components . 

 

 

 

 

 

Summary of Contents for PDC125

Page 1: ...MANUAL DE USO Y MANTENIMIENTO VITRINA EXPOSITORA PDC125 90 USER AND MANTINANCE MANUAL POOL DISPLAY COUNTER PDC125 90 MANUEL D UTILISATION ET D ENTRETIEN VITRINE GAMME R FRIG R E PDC125 90...

Page 2: ...1 manual de uso ESPA OL PAG 3 user manual ENGLISH PG 13 manual d utilisation FRAN AIS PAGE 23 TEFCOLD EMPRESA CERTIFICADA Zona n de serie...

Page 3: ...2...

Page 4: ...NDICIONES DE USO 5 PUESTA EN MARCHA 6 RECOMENDACIONES 7 PRECAUCIONES 8 MANTENIMIENTO 9 PRUEBAS DE FUCIONAMIENTO 10 RETIRADA DEL SERVICIO 11 ESQUEMA EL CTRICO 12 ESQUEMA FRIGOR FICO ANEXO NORMATIVA ANE...

Page 5: ...tos en la alimentaci n el ctrica Modificaciones o intervenciones no autorizadas Uso de recambios no espec ficos para el modelo Incumplimiento total o parcial de las instrucciones Incidencias motivadas...

Page 6: ...metida o a una bandeja extra ble manualmente PRIMERA LIMPIEZA Primero retire el film protector del acero utilizando alg n objeto no punzante y retirando los restos de adhesivo con alcohol Evitar absol...

Page 7: ...ITORAS est n preparadas para la conservaci n de productos frescos o alimentos precocinados as como la refrigeraci n de bebidas El rango de temperaturas del equipodebe ser seleccionado considerando los...

Page 8: ...as como la debida protecci n del magneto t rmico y diferencial La red de alimentaci n debe tener la secci n adecuada para el consumo del aparato Si varios equipos se instalan alineados deben ser cone...

Page 9: ...or fico Desconectar el interruptor general y desenchufar la unidad Limpiar interior y exterior del aparato Abrir parcialmente la puerta para permitir la circulaci n de aire y de este modo evitar malos...

Page 10: ...duros o punzantes Para la limpieza de la bater a o de la carcasa NO se deben utilizar desengrasantes qu micos con componentes cidos o lej as cloro o amon aco as como las sales ya que todos estos prod...

Page 11: ...nciales En caso que dichos controles hayan dado resultado negativo dir jase al servicio de asistencia de su zona facilitando las siguientes indicaciones sobre el modelo n mero de serie y matr cula ind...

Page 12: ...osible existencia de plomo mercurio cromo hexavalente polibromobifenilos PBB y tambi n difenil ter PBDE no alcanza en peso el 0 01 Esta declaraci n est basada en las declaraciones de nuestros proveedo...

Page 13: ...ntera Efect e la limpieza del equipo con sumo cuidado utilizando para los cambiadores de calor un pincel suave aire comprimido o un equipo de aspiraci n adecuado para no da arlos Ubique el equipo en u...

Page 14: ...CHARACTERISTICS AND CONDITIONS OF USE 5 START UP 6 RECOMMENDATIONS 7 PRECAUTIONS 8 MAINTENANCE 9 OPERATIONAL TESTS 10 DECOMMISSIONING 11 ELECTRIC SHEME 12 COLD SHEME ANNEX NORMATIVE ANNEX INSTALLATION...

Page 15: ...urchased unit Possible damage to person of property caused by improper installation Installation not carried out following the procedures described in this manual Defects in the electricity supply Una...

Page 16: ...The unit is equipped with drain cleaning we recommend connecting it directly to the appropriate device or a receptacle should be positioned in order to collect the water FIRST CLEANING First of all r...

Page 17: ...to conserve fresh products or pre cooked foods as well as the refrigeration of drinks The range of temperatures of the unit must be selected taking into account the following points Type of product fo...

Page 18: ...d differential magnetic protection The power supply must have the suitable section for the consumption of the appliance If various units are installed in a row each one must be connected independently...

Page 19: ...n of air The maximum weight for glass shelf will is 8 kg m distributed evenly and 60kg mfor shelf exposure When the unit has to be turned off for a long period of time the following steps are recommen...

Page 20: ...casing DO NOT use chemical de greasers with acid compounds or bleach chlorine ammonia or salts as all these products aggressively attack copper and aluminium Only water with well diluted neutral dete...

Page 21: ...e refrigerator cabinet containing polyurethane foam oil plastic parts metal parts and electrical and electronic components When the life of the furniture has come to an end and is necessary to remove...

Page 22: ...21 11 ELECTRIC SCHEME 12 COLD SCHEME...

Page 23: ...compressed air or suitable suction equipment for not damaging them Place the equipment in a large room to avoid the possible formation of explosive gas air mixture in case of leakage The room must ha...

Page 24: ...S ET CONDITIONS D UTILISATION 5 MISE EN MARCHE 6 RECOMMANDATIONS 7 PR CAUTIONS 8 ENTRETIEN 9 TEST DE FONCTIONNEMENT 10 RETRAIT DE SERVICE 11 SCH MA LECTRIQUE 12 SCH MA FROID ANNEXE R GLEMENT ANNEXE IN...

Page 25: ...les proc dures d crites dans ce manuel D fections de l alimentation lectrique Modifications ou interventions non autoris es Utilisation de pi ces de rechange n tant pas sp cifiques au mod le Non obser...

Page 26: ...un nettoyage de vidange il est conseill de se connecter un r seau de branchement ou un plateau amovible manuellement PREMIER NETTOYAGE Enlever d abord le film prot geant l acier avec l aide d un objet...

Page 27: ...eil doit tre branch seront galement indiqu es Les vitrines r frig r es servant conserver des produits frais ou des aliments pr cuisin s ainsi qu conserver au froid les boissons La plage de temp rature...

Page 28: ...lectrique laquelle le meuble sera branch dispose d une PRISE DE TERRE ainsi que d une protection appropri e du disjoncteur magn tothermique et diff rentiel Le r seau d alimentation doit tre dot d une...

Page 29: ...possible d ouvrir fr quemment les portes et surtout ne jamais les laisser ouvertes Eviter de mettre des feuilles cartonn es ou du papier sur les tag res tant donn que cela emp che l air de circuler Le...

Page 30: ...seill que cette op ration soit effectu e par le service technique En cas de doute veuillez contacter votre distributeur Il est conseill d ex cuter cette op ration au moins tous les trois mois et en d...

Page 31: ...ifier l quilibre du meuble car il peut tre l origine de vibrations V rifier qu aucun objet ne fr le un l ment mobile du frigidaire TESTS SONORES Les tests sonores sont ex cut s dans une salle sans auc...

Page 32: ...auquel ce manuel fait r f rence r pond aux exigences de la directive 2002 95 CE RoHS Dans tous les mat riaux homog nes utilis s pour la fabrication l existence ventuelle de plomb le mercure le chrome...

Page 33: ...air comprim ou une quipe d aspiration appropri pour ne pas les endommager Placez l appareil dans une grande salle pour viter la formation possible de m lange gaz air explosif en cas de fuite La chambr...

Page 34: ...83 900x971x734 Refrigerated shelf area m2 1 17 0 48 Total display rea m2 1 27 0 68 Visibility of products by arc method m2 0 57 0 31 Net volume l 176 107 Maximum load in shelf kg 30 30 Location of the...

Page 35: ...NNEX INSTALLATION ANNEXE INSTALLATION Siempre atornille manualmente no utilice herramientas el ctricas Always screw manually do not use electrical tools Toujours visser manuellement ne pas utiliser d...

Page 36: ...35 5 3 4...

Page 37: ...36 Deje funcionando la vitrina 1 hora sin producto Leave working serve over counter 1 hour without product Laissez la fen tre en cours d ex cution 1 heure sans produit 6 1 2 3...

Page 38: ...37 ANEXO REGULACI N PLANO EXPOSICI N SOLO PDC125 ANNEX DISPLAY AREA REGULATION ONLY PDC125 ANNEXE R GLEMENT DE LA SURFACE D EXPOSITION SEUL PDC125 4 7 11 1 2 0...

Page 39: ...38 3...

Page 40: ...39...

Reviews: