background image

 

14 

 

We would like thank you for your confidence in us for having purchased this refrigerated unit. This manual has been prepared ing order to 

safeguard the security of the user and ensure the correct use and maintenance of the refrigerated units. Please read it carefully before starting 

up your unit. The refrigeration unit strictly complies with all applicable European directives and standards. 

 

1. WARNING

 

Before carrying out any operation, whether as installation technician or as the user of the unit, you should be aware of the points explained in 

this manual. 

This manual should be kept in a safe place and should be available for reference. In case of loss, request a duplicated indicating model, serial 

number and date of purchase.  

The manufacturer considers that both the installation technician and the user of the unit must have the most basic training in order to 

understand the contents of this manual, as well as an awareness of standard hygiene and safety principal. 

If required, this unit must be repaired exclusively by qualified technical personnel. 

ATTENTION 

Access to all electrical part of the unit, either installation or maintenance issues, is authorized qualified personnel only. 

The user will be responsible for the following items: 

 

Suitability of the premises to the requirements of the purchased unit. 

 

Electricity supply in accordance with the current standards and sufficient for the consumption and safety of the unit. 

 

Material necessary to clean the unit. 

 

Water point or drainage outlet as necessary for the installation of the refrigerated unit. 

The manufacturer disclaims all liability in the following situations: 

 

Inappropriate use of the purchased unit. 

 

Possible damage to person of property caused by improper installation. 

 

Installation not carried out following the procedures described in this manual. 

 

Defects in the electricity supply. 

 

Unauthorised modifications or interventions. 

 

Use of spares not specific to the model.  

 

Total or partial non-compliance with the instructions. 

 

Incidents caused by transportations company or movement of the unit to its place of installation. 

 

All ventilation grilles should be kept clear of obstruction and not covered by secondary decorative panelling. 

 

In High humidity periods it may be necessary to perform additional defrosts by pressing the manual defrost button on the controller, It 

is recommended to switch off the unit once a month to thoroughly clean the cabinet interior and allow any ice build up to be fully 

defrosted. 

 

Avoid locations where excessive air movement can be directed into the refrigerated area of the cabinet, special attention to the 

location of air conditioners and oscillating fans. 

 

For any questions you need to contact your dealer. 

 

 

2. GUARANTEE 

 

The guarantee for the unit and the parts that comprise it are guaranteed for one year starting from the date of sale and consists of the 

replacement (carriage unpaid) of the detective component or component, provided that it is not as a result of the misuse of the same. 

The guarantee doesn’t include labor resulting from the replacement of components. 

The guarantee will not cover breakdown or breakage of components, even when the same occurs within the established period, arising from 

subjecting the unit to working conditions other than those established in this manual and the details of each model contained in the catalogue 

(failure in the power supply, high ambient temperatures, windows, lighting, etc…). 

The manufacturers guarantee excludes consequential loss arising from any component failure.

 

 

 

 

 

 

Summary of Contents for PDC125

Page 1: ...MANUAL DE USO Y MANTENIMIENTO VITRINA EXPOSITORA PDC125 90 USER AND MANTINANCE MANUAL POOL DISPLAY COUNTER PDC125 90 MANUEL D UTILISATION ET D ENTRETIEN VITRINE GAMME R FRIG R E PDC125 90...

Page 2: ...1 manual de uso ESPA OL PAG 3 user manual ENGLISH PG 13 manual d utilisation FRAN AIS PAGE 23 TEFCOLD EMPRESA CERTIFICADA Zona n de serie...

Page 3: ...2...

Page 4: ...NDICIONES DE USO 5 PUESTA EN MARCHA 6 RECOMENDACIONES 7 PRECAUCIONES 8 MANTENIMIENTO 9 PRUEBAS DE FUCIONAMIENTO 10 RETIRADA DEL SERVICIO 11 ESQUEMA EL CTRICO 12 ESQUEMA FRIGOR FICO ANEXO NORMATIVA ANE...

Page 5: ...tos en la alimentaci n el ctrica Modificaciones o intervenciones no autorizadas Uso de recambios no espec ficos para el modelo Incumplimiento total o parcial de las instrucciones Incidencias motivadas...

Page 6: ...metida o a una bandeja extra ble manualmente PRIMERA LIMPIEZA Primero retire el film protector del acero utilizando alg n objeto no punzante y retirando los restos de adhesivo con alcohol Evitar absol...

Page 7: ...ITORAS est n preparadas para la conservaci n de productos frescos o alimentos precocinados as como la refrigeraci n de bebidas El rango de temperaturas del equipodebe ser seleccionado considerando los...

Page 8: ...as como la debida protecci n del magneto t rmico y diferencial La red de alimentaci n debe tener la secci n adecuada para el consumo del aparato Si varios equipos se instalan alineados deben ser cone...

Page 9: ...or fico Desconectar el interruptor general y desenchufar la unidad Limpiar interior y exterior del aparato Abrir parcialmente la puerta para permitir la circulaci n de aire y de este modo evitar malos...

Page 10: ...duros o punzantes Para la limpieza de la bater a o de la carcasa NO se deben utilizar desengrasantes qu micos con componentes cidos o lej as cloro o amon aco as como las sales ya que todos estos prod...

Page 11: ...nciales En caso que dichos controles hayan dado resultado negativo dir jase al servicio de asistencia de su zona facilitando las siguientes indicaciones sobre el modelo n mero de serie y matr cula ind...

Page 12: ...osible existencia de plomo mercurio cromo hexavalente polibromobifenilos PBB y tambi n difenil ter PBDE no alcanza en peso el 0 01 Esta declaraci n est basada en las declaraciones de nuestros proveedo...

Page 13: ...ntera Efect e la limpieza del equipo con sumo cuidado utilizando para los cambiadores de calor un pincel suave aire comprimido o un equipo de aspiraci n adecuado para no da arlos Ubique el equipo en u...

Page 14: ...CHARACTERISTICS AND CONDITIONS OF USE 5 START UP 6 RECOMMENDATIONS 7 PRECAUTIONS 8 MAINTENANCE 9 OPERATIONAL TESTS 10 DECOMMISSIONING 11 ELECTRIC SHEME 12 COLD SHEME ANNEX NORMATIVE ANNEX INSTALLATION...

Page 15: ...urchased unit Possible damage to person of property caused by improper installation Installation not carried out following the procedures described in this manual Defects in the electricity supply Una...

Page 16: ...The unit is equipped with drain cleaning we recommend connecting it directly to the appropriate device or a receptacle should be positioned in order to collect the water FIRST CLEANING First of all r...

Page 17: ...to conserve fresh products or pre cooked foods as well as the refrigeration of drinks The range of temperatures of the unit must be selected taking into account the following points Type of product fo...

Page 18: ...d differential magnetic protection The power supply must have the suitable section for the consumption of the appliance If various units are installed in a row each one must be connected independently...

Page 19: ...n of air The maximum weight for glass shelf will is 8 kg m distributed evenly and 60kg mfor shelf exposure When the unit has to be turned off for a long period of time the following steps are recommen...

Page 20: ...casing DO NOT use chemical de greasers with acid compounds or bleach chlorine ammonia or salts as all these products aggressively attack copper and aluminium Only water with well diluted neutral dete...

Page 21: ...e refrigerator cabinet containing polyurethane foam oil plastic parts metal parts and electrical and electronic components When the life of the furniture has come to an end and is necessary to remove...

Page 22: ...21 11 ELECTRIC SCHEME 12 COLD SCHEME...

Page 23: ...compressed air or suitable suction equipment for not damaging them Place the equipment in a large room to avoid the possible formation of explosive gas air mixture in case of leakage The room must ha...

Page 24: ...S ET CONDITIONS D UTILISATION 5 MISE EN MARCHE 6 RECOMMANDATIONS 7 PR CAUTIONS 8 ENTRETIEN 9 TEST DE FONCTIONNEMENT 10 RETRAIT DE SERVICE 11 SCH MA LECTRIQUE 12 SCH MA FROID ANNEXE R GLEMENT ANNEXE IN...

Page 25: ...les proc dures d crites dans ce manuel D fections de l alimentation lectrique Modifications ou interventions non autoris es Utilisation de pi ces de rechange n tant pas sp cifiques au mod le Non obser...

Page 26: ...un nettoyage de vidange il est conseill de se connecter un r seau de branchement ou un plateau amovible manuellement PREMIER NETTOYAGE Enlever d abord le film prot geant l acier avec l aide d un objet...

Page 27: ...eil doit tre branch seront galement indiqu es Les vitrines r frig r es servant conserver des produits frais ou des aliments pr cuisin s ainsi qu conserver au froid les boissons La plage de temp rature...

Page 28: ...lectrique laquelle le meuble sera branch dispose d une PRISE DE TERRE ainsi que d une protection appropri e du disjoncteur magn tothermique et diff rentiel Le r seau d alimentation doit tre dot d une...

Page 29: ...possible d ouvrir fr quemment les portes et surtout ne jamais les laisser ouvertes Eviter de mettre des feuilles cartonn es ou du papier sur les tag res tant donn que cela emp che l air de circuler Le...

Page 30: ...seill que cette op ration soit effectu e par le service technique En cas de doute veuillez contacter votre distributeur Il est conseill d ex cuter cette op ration au moins tous les trois mois et en d...

Page 31: ...ifier l quilibre du meuble car il peut tre l origine de vibrations V rifier qu aucun objet ne fr le un l ment mobile du frigidaire TESTS SONORES Les tests sonores sont ex cut s dans une salle sans auc...

Page 32: ...auquel ce manuel fait r f rence r pond aux exigences de la directive 2002 95 CE RoHS Dans tous les mat riaux homog nes utilis s pour la fabrication l existence ventuelle de plomb le mercure le chrome...

Page 33: ...air comprim ou une quipe d aspiration appropri pour ne pas les endommager Placez l appareil dans une grande salle pour viter la formation possible de m lange gaz air explosif en cas de fuite La chambr...

Page 34: ...83 900x971x734 Refrigerated shelf area m2 1 17 0 48 Total display rea m2 1 27 0 68 Visibility of products by arc method m2 0 57 0 31 Net volume l 176 107 Maximum load in shelf kg 30 30 Location of the...

Page 35: ...NNEX INSTALLATION ANNEXE INSTALLATION Siempre atornille manualmente no utilice herramientas el ctricas Always screw manually do not use electrical tools Toujours visser manuellement ne pas utiliser d...

Page 36: ...35 5 3 4...

Page 37: ...36 Deje funcionando la vitrina 1 hora sin producto Leave working serve over counter 1 hour without product Laissez la fen tre en cours d ex cution 1 heure sans produit 6 1 2 3...

Page 38: ...37 ANEXO REGULACI N PLANO EXPOSICI N SOLO PDC125 ANNEX DISPLAY AREA REGULATION ONLY PDC125 ANNEXE R GLEMENT DE LA SURFACE D EXPOSITION SEUL PDC125 4 7 11 1 2 0...

Page 39: ...38 3...

Page 40: ...39...

Reviews: