![teel 4RJ40 Operating Instructions & Parts Manual Download Page 11](http://html1.mh-extra.com/html/teel/4rj40/4rj40_operating-instructions-and-parts-manual_1073410011.webp)
Models 4RJ40, 4RJ41, 4RJ42, 4RJ43 and 4RJ44
11
Teel Operating Instructions and Parts Manual
E
N
G
L
I
S
H
®
Symptom
Possible Cause(s)
Corrective Action
Motor will not run
1. Disconnect switch is OFF
1. Be sure the switch is ON
2. Fuse is blown or circuit breaker tripped
2. Replace fuse or reset circuit breaker
3. Starting switch is defective
3. DISCONNECT POWER; Replace starting switch
4. Wires at motor are loose, disconnected,
4. Refer to instructions on wiring (Page 5).
or wired incorrectly
DISCONNECT POWER; check and tighten all wiring
Motor runs hot and
1. Motor is wired incorrectly
1. Refer to instructions on wiring
overload kicks OFF
2. Voltage is too low
2. Check voltage being supplied to motor.
or motor does not
Install heavier wiring if wire size is too small
run and only hums
(See Electrical/Wiring Chart)
Motor runs but no
Pump in new installation did not pick
In new installation:
water is delivered
up prime through:
1. Improper priming
1. Re-prime according to instructions
2. Air leaks
2. Check all connections on suction line, with soapy
water or shaving cream
3. Leaking foot valve or check valve
3. Replace foot valve or check valve
4. Pipe size too small
4. Re-pipe using size of suction and discharge
ports on pump
Pump has lost prime through:
In installation already in use:
5. Air leaks
5. Check all connections on suction line and shaft
seal with soapy water
6. Water level below suction pipe inlet
6. Lower suction line into water and re-prime. If
receding water level in well exceeds 20’, a deep
well pump is needed
7.
Impeller is plugged
7. Clean impeller
8. Check valve or foot valve is stuck shut
8. Replace check valve or foot valve
9. Pipes are frozen
9. Thaw pipes. Bury pipes below frost line. Heat pit
or pump house
10. Foot valve and/or strainer are buried
10. Raise foot valve and/or strainer above bottom of
in sand or mud
water source. Clean foot valve and strainer
Troubleshooting Chart
Read and understand safety and
operating instructions in this
manual before doing any work on pump!
Only qualified personnel should
electrically test pump motor.
Capacitor voltage
may be hazardous.
To discharge capacitor, hold insulated
handle screwdriver BY THE HANDLE and
short terminals together. Do not touch
metal screwdriver blade or capacitor
terminals. If in doubt, consult a qualified
electrician.
NOTE:
Stop pump;
then check prime
before looking for
other causes.
Unscrew priming
plug and see if
water is in priming
hole