Symptom

Possible Cause(s)

Corrective Action

Motor will not run

1. Disconnect switch is OFF

1. Be sure the switch is ON

2. Fuse is blown or circuit breaker tripped

2. Replace fuse or reset circuit breaker

3. Starting switch is defective

3. DISCONNECT POWER; Replace starting switch

4. Wires at motor are loose, disconnected, 

4. Refer to instructions on wiring (Page 5). 

or wired incorrectly

DISCONNECT POWER; check and tighten all wiring

Motor runs hot and 

1. Motor is wired incorrectly

1. Refer to instructions on wiring

overload kicks OFF

2. Voltage is too low

2. Check voltage being supplied to motor.  

or motor does not  

Install heavier wiring if wire size is too small  

run and only hums

(See Electrical/Wiring Chart)

Motor runs but no 

Pump in new installation did not pick 

In new installation:

water is delivered

up prime through:

1. Improper priming

1. Re-prime according to instructions

2. Air leaks

2. Check all connections on suction line, with soapy

water or shaving cream

3. Leaking foot valve or check valve

3. Replace foot valve or check valve

4. Pipe size too small

4. Re-pipe using size of suction and discharge 

ports on pump

Pump has lost prime through:

In installation already in use:

5. Air leaks

5. Check all connections on suction line and shaft 

seal with soapy water

6. Water level below suction pipe inlet

6. Lower suction line into water and re-prime. If 

receding water level in well exceeds 20’, a deep 
well pump is needed

7.

Impeller is plugged

7. Clean impeller

8. Check valve or foot valve is stuck shut

8. Replace check valve or foot valve

9. Pipes are frozen

9. Thaw pipes. Bury pipes below frost line. Heat pit 

or pump house

10. Foot valve and/or strainer are buried 

10. Raise foot valve and/or strainer above bottom of

in sand or mud

water source. Clean foot valve and strainer

Troubleshooting Chart

Read and understand safety and

operating instructions in this

manual before doing any work on pump!

Only qualified personnel should

electrically test pump motor.

Capacitor voltage

may be hazardous.

To discharge capacitor, hold insulated
handle screwdriver BY THE HANDLE and
short terminals together. Do not touch
metal screwdriver blade or capacitor
terminals. If in doubt, consult a qualified
electrician.

NOTE: 

Stop pump;

then check prime
before looking for
other causes.
Unscrew priming
plug and see if
water is in priming
hole

Summary of Contents for 4RJ40

Page 1: ...manual and on pump 4RJ40 Fiberglass Reinforced Thermoplastic Engineered Polymer Viton Polypropylene 4RJ41 Fiberglass Reinforced Thermoplastic Engineered Polymer Viton Polypropylene 4RJ42 Fiberglass R...

Page 2: ...d tools and equipment Keep visitors at a safe distance from the work areas Make workshop childproof with padlocks master switches and by removing starter keys Know the pump application limitations and...

Page 3: ...s WELL PIPE INSTALLATION NOTE Use installation method below which matches your well type CASED WELL DUG WELL INSTALLATION 1 Inspect foot valve to be sure it works freely Inspect strainer to be sure it...

Page 4: ...ight If the suction pipe can suck air the pump will not be able to pull water from the well 1 Bolt pump to solid level foundation See Figure 4 2 Support all piping connected to pump See Figure 5 3 Wra...

Page 5: ...expected power application 4 Ground the pump permanently using a wire of the same size as that specified in wiring chart Page 4 Make ground connection to green grounding terminal in motor junction box...

Page 6: ...ll and try again NEVER run pump against closed discharge To do so can boil water inside pump causing hazardous pressure in unit risk of explosion and possibly scalding persons handling pump See Figure...

Page 7: ...or Remove rotating half of seal by placing two screwdrivers under back half of pump body and carefully prying up See Figure 12 Back half of pump body will slide off shaft bringing seal with it NOTE Be...

Page 8: ...automatically locate seal in correct position 10 Remount diffuser on pump body half with five screws 11 Reinstall motor canopy and tighten three capscrews to hold it INSTALLING HEAT SINK 2 AND 21 2 HP...

Page 9: ...ear ring C1 258PCASS C1 258PCASS C1 258PCASS 1 9 8 32 x 1 Screw stainless steel 3 10 Clamp C19 54SS C19 54SS C19 54SS 1 11 Pump body C176 66P C176 66P C176 66P 1 12 1 4 NPT Drain plug WC78 40T WC78 40...

Page 10: ...SA 1 9 8 32 x 1 Screw stainless steel 2 10 Clamp C19 37A C19 37A 1 11 Pump body C176 62P C176 62P 1 12 Priming plug WC78 39T WC78 39T 1 13 1 4 NPT Drain plug WC78 40T WC78 40T 1 14 Diffuser O Ring U9...

Page 11: ...foot valve or check valve 4 Pipe size too small 4 Re pipe using size of suction and discharge ports on pump Pump has lost prime through In installation already in use 5 Air leaks 5 Check all connecti...

Page 12: ...strations or descriptions Except as provided below no warranty or affirmation of fact expressed or implied other than as stated in the LIMITED WARRANTY above is made or authorized by Dayton PRODUCT SU...

Reviews: