Pump operates

1. Pressure switch

1. Readjust switch to lower shut-off pressure setting.

properly, but

Clean contacts or replace switch

won’t shut off

2. Low water level

2. Throttle pump output at gate valve or readjust

pressure switch to lower shut-off pressure setting

3. Leak in drop pipe or worn pump

3. Throttle pump output at gate valve or readjust

pressure switch to lower shut-off pressure setting.
If pump does not shut off, pump must be raised
and defect repaired

Pump starts too 

1. Pressure switch

1. Readjust switch to wider operating pressure limits. 

often

Replace defective switch

2. Air volume in tank incorrect

2. Shut pump off, drain tank completely. Restart unit;

if tank waterlogs again within a few days, clean or
replace air volume control, used on standard tanks.
Precharged, fixed diaphragm or bladder

3. Check valve defect or leak in

3. Throttle pump output at gate valve. If pump does

drop pipe

not shut off, pump must be raised and defect
repaired

Symptom

Possible Cause(s)

Corrective Action

Troubleshooting Chart (Continued)

General Procedures

1. Disconnect line

(Power to control

2. Inspect for damaged or burned parts, loose connections, etc.

box disconnected)

3. Check for misconnections against diagram in control box
4. If box is too hot, circuit breakers may trip or fuses blow. Ventilate or shade box.

Move away from heat source

5. If problem has not been found, check motor and control box. Use test procedures

that follow

Ground (Insulation

1. Ohmmeter Setting: Highest scale (usually Rx100K or Rx10,000)

Resistance) Test

2. Terminal Connections: One ohmmeter lead to “Ground” screw on control box and touch

(Power to control

other lead to each of the terminals on terminal board

box disconnected)

3. Ohmmeter Reading: Pointer should remain at infinity (

) and not deflect

Risk of electrical shock. 
Short capacitor across terminals before testing.

Capacitor Tests

1. Ohmmeter Setting: Rx1000

(Power to control

2. Terminal connections: Connect ohmmeter leads to black and orange wires out of capacitor case

box disconnected)

3. Ohmmeter Reading: Pointer should swing toward “zero” and “float” back to (

). Capacitor

is shorted if pointer does not move back to (

), open if it does move from (

)

4. To retest capacitor, reverse ohmmeter connection to capacitor terminals

Triac Test

1. Ohmmeter Setting: Rx1000

(Solid state

2. Connect the leads to “R” (start) terminal and to orange lead on start switch

switch only)

3. Ohmmeter Reading: Infinity (

)

Coil Test

1. Ohmmeter Setting: Rx1

(Solid state

2. Connect leads to “Y” (common) and L2 terminal and to orange lead terminal on start switch

switch only)

3. Ohmmeter Reading: Infinity (

)

Test

Procedure

Control Box Test Chart

Manufactured for Dayton Electric Mfg. Co.
Niles, Illinois  60714  U.S.A.

®

4P847A thru 4P851A, 4P852 thru 4P865, 4RH01 thru 4RH06, 

4RG76 thru 4RG84, 4RG94 thru 4RG97 and 4RG99

Summary of Contents for 4P847A

Page 1: ...94 thru 4RG97 and 4RG99 are thermoplastic discharge Pumps 4P847A thru 4P851A and 4P852 thru 4P856 are cast iron discharge E N G L I S H Printed in U S A 09319 0798 116 E3 4P847A 1 3 10 3 4P840 5 115 6...

Page 2: ...RK69 4P854 40 9 5 7 5 4 3 50 7 2 3 8 60 3 7 4P855 20 15 6 14 8 14 0 13 0 11 8 10 2 8 2 2 1 4P837 4P856 30 14 6 13 7 12 8 11 6 10 3 8 3 6 0 4RK69 4P857 40 13 6 12 6 11 5 10 1 8 6 6 1 2 8 4P858 50 12 5...

Page 3: ...on 230 volt installations to prevent motor damage 7 Be sure to provide adequate ventilation for pressure switch and control box to prevent moisture damage to components 8 Periodically check well seal...

Page 4: ...its are supplied with extra label for above ground pump identification Place label in conspicuous location on control box etc for future reference 2 Check electrical supply for correct fusing wire siz...

Page 5: ...time selector switch is changed 2 Clip one ohmmeter lead to bare cable end 3 Clip the other lead to edge of steel tank in which pump and cable are submerged If pump is already in the well clip lead t...

Page 6: ...2 If replacing a jet pump expect to set the submersible deeper in the well because the submersible will pump more water than the jet pump Be sure the new submersible is set at least ten feet above the...

Page 7: ...astic pipe adapter in the pump discharge tapping using pipe joint compound or teflon tape Models 4P847A thru 4P851A 4P852 thru 4P865 4RH01 thru 4RH06 4RG76 thru 4RG84 4RG94 thru 4RG97 and 4RG99 7 Teel...

Page 8: ...he pipe f If you have not already done so splice the electrical cable to the motor wire leads according to the directions under Sections 5 6 and 7 in Preinstallation g Unroll electrical cable alongsid...

Page 9: ...the pipe to eliminate rubbing against well casing Leave four to five feet of slack at the upper end to allow for plastic pipe stretch 5 Tie safety rope to top of pump in holes provided Tape end of ro...

Page 10: ...Use ONLY submersible cable to pump 7 Two wire pump hookup Wire the fused electrical disconnect box to water system pressure switch and from pressure switch to motor See Figures 15 and 16A Power cable...

Page 11: ...230 1 3 6 0 7 4 26 1 32 32 1 39 4 4 6 4 6 0 15 5 4P853 4P849A 4RG99 230 1 2 4 2 5 2 16 7 20 5 20 9 25 7 6 0 6 0 0 15 7 4P856 4RG76 4P851A 4RH01 230 3 4 3 0 3 6 11 0 13 4 14 0 17 0 8 0 8 0 0 20 9 4P85...

Page 12: ...itively identified proceed as follows 1 Disconnect all three drop cables from the control box For temporary identification tie a numbered tag to each cable 1 2 3 2 Using an ohmmeter check the resistan...

Page 13: ...l rights which vary from jurisdiction to jurisdiction LIMITATION OF LIABILITY To the extent allowable under applicable law Dayton s liability for consequential and incidental damages is expressly disc...

Page 14: ...L10P4DS WG 4P860 1D125 L10P4DS WG 4P861 1D133 4P845 L10P4ES WG 4P862 1D134 4P846 L10P4FS WG 4P863 1D133 4P845 L20P4ES WG 4P864 1D126 L20P4ES WG 4P865 1D134 4P846 L20P4FS WG 4RG99 1D131 4P843 L5P4CJL W...

Page 15: ...one minute intervals no water 2 Gas or air in well water 2 Connect hose to service valve Run water thru hose submerged in water in clear jar Observe for air bubbles from hose outlet If tank is standar...

Page 16: ...t circuit breakers may trip or fuses blow Ventilate or shade box Move away from heat source 5 If problem has not been found check motor and control box Use test procedures that follow Ground Insulatio...

Reviews: