background image

10

98-05334-EN R2

DynaJet

®

 Flex

Ready to pressure test the system

1.  Ensure that current rate control system is operating at the 

optimum level. Set DynaJet operating mode to manual and set 

PWM duty cycle at 100%. This will make the system operate as if 

DynaJet was not present. Use this configuration to verify the rate 

control system is operating normally.

2.  Keep DynaJet operating mode on manual and change PWM 

duty cycle to 50%. Use this configuration to verify the rate control 

system is operating normally.

3. 

Confirm boom section functionality by observing the row of 

rectangles below the on the operating display.

4.  Switch the master switch ON (on rate control or other boom 

section control switches) and individual sections one at a time 

Make sure each section appropriately changes colour to blue. 

With the master switch off, all active sections will be grey again.

5. 

Start pump and ensure no leaks.

6.  Verify pressure on mechanical gauge matches the digital 

pressure display within reason. If not, adjust maximum pressure 

sensor value as previously described.

7. 

Configure in PWM mode DynaJet at duty cycle of 50%. Confirm 

each e-ChemSaver (ECS) is pulsating.

At this point the system is functioning. Further details for fine-tuning 

the system are available in the user settings section of this guide.

Work screen

On screen indicators

Current droplet size – displays the current droplet size using both the 

appropriate colour droplet icon and size letter code.
PWM duty cycle – displays the current PWM duty cycle as a 

percentage.

Active solenoid (high flow mode only) – displays if one or both sets of 

solenoid are active.
Actual pressure – displays the actual pressure.
Current nozzle selection – displays the current selected nozzle.
Boom status

►Blue – turned on (standard mode or high flow mode single 

solenoid active)

►Green – turned on (high flow mode both solenoids active)
►Empty – turned off

Pressure gauge

►Red diamond – actual pressure
►Colors – droplet size,

Operation modes

►Nozzle mode (pressure) – when the user changes the desired 

drop sizes choices (via the droplet size selectors checkboxes) 

the system will recalculate the desired pressure. It will then 

adjust the PWM duty cycle to attempt to attain the desired 

pressure in the system.

►Manual mode (PWM) – the user can manually adjust the 

PWM duty cycle to attempt to attain the desired pressure in 

the system.

Droplet size selectors

►Red X and greyed out – not selected

High flow mode

►Single – one set of solenoids active
►Dual  – both sets of solenoids active

Droplet size chart

When choosing a spray nozzle that produces droplet sizes in one 

of the eight droplet size classification categories, it is important to 

remember that a single nozzle can produce different droplet size 

classifications at different pressures. A nozzle might produce medium 

droplets at low pressures, while producing fine droplets as pressure 

is increased.

Category

Symbol

Color code

Extremely fine

XF

Violet

Very fine

VF

Red

Fine

F

Orange

Medium

M

Yellow

Coarse

C

Blue

Very coarse

VC

Green

Extremely coarse

XC

White

Ultra coarse

UC

Black

Summary of Contents for DynaJet Flex 7120

Page 1: ...D Y N A J E T F L E X INSTALLATION SETUP AND USER GUIDE Software version 1 02 with optional high flow option...

Page 2: ...t names are trademarks or registered trademarks of their respective companies or organizations Limitation of Liability TEEJET TECHNOLOGIES PROVIDES THIS MATERIAL AS IS WITHOUT WARRANTY OF ANY KIND EIT...

Page 3: ...les 5 Boom harnesses 5 Pressure sensor 5 DynaJet 7120 console 5 Other battery cable 5 INITIAL STARTUP 8 Favorites 8 Setup 8 Units 9 Number of sections 9 Maximum pressure sensor value 9 Nozzle selectio...

Page 4: ...Jet Flex console is designed to provide years of service under typical agricultural and turf operating conditions A tight fitting enclosure means that typical dusty environments will not cause operati...

Page 5: ...nator Female Start 35 50048 DynaJet Solenoid 45 05943 Battery 60 AMP Fuse Cable 78 05121 xx Power Distribution Module 45 05971 xx Driver to Power Extension Cable 45 05980 xx Driver to Power Y Cable 45...

Page 6: ...Power will then route from 78 05121 xx to each DynaJet driver 78 05122 using cables 45 05971 xx Figure 2 Installation diagram standard mode Nozzle harnesses When installing nozzle harnesses 45 05935...

Page 7: ...outputs If not using 45 10142 some machine specific harnesses are available The BIM can be mounted in the cab or outside depending upon your installation DynaJet interface The DynaJet interface 78 051...

Page 8: ...the J end terminator 45 05856 to M 4 nozzle harness 9 12 45 10176 last section Nozzle harnesses Step 3 install nozzle harness K 4 nozzle harness 1 4 45 10174 L 4 nozzle harness 5 8 45 10175 and M 4 n...

Page 9: ...zzle Harness 1 4 A 90 02887 DynaJet 7120 Console w RAM Mount Kit Kit includes Console and Mount Sensor Cable Pressure Sensor I 45 05855 CAN Terminator Female Start t o B a t t e r y P o w e r t o B a...

Page 10: ...F interface E 45 05857 1 m 45 05858 2 m 45 05859 4 m 45 05864 10 5 m CAN extension cable F 78 05124 DynaJet HF driver G 90 04007 3 m 90 04008 10 m DynaJet pressure sensor interface kit H 45 10178 to I...

Page 11: ...Nozzle selection the SPRAY NOZZLE icon is used to select the spray nozzle style and capacity Once chosen here the spray nozzle style and capacity is automatically added to the favorites list 2 Press H...

Page 12: ...easing the value will reduce the pressure value displayed during operation Decreasing this value will increase the pressure value displayed during operation Figure 10 Maximum pressure sensor value Noz...

Page 13: ...r droplet icon and size letter code PWM duty cycle displays the current PWM duty cycle as a percentage Active solenoid high flow mode only displays if one or both sets of solenoid are active Actual pr...

Page 14: ...tions concerning the setup of the DynaJet Flex please contact your dealer or TeeJet customer service representative for clarification before operation TeeJet technologies is not responsible for misuse...

Page 15: ...30 Fine gain settings are 1 10 as powerful gain as coarse gain settings Coarse gain This is the more aggressive gain setting and will have the largest impact on the stability and function of the Dyna...

Page 16: ...plication rate and droplet size 3 Fine tune the regulation performance of the rate control system and the DynaJet system a Typical settings used for DynaJet fine tuning include fine gain coarse gain c...

Page 17: ...hat produces the target application rate at a duty cycle of about 70 when running at expected travel speeds In other words choose nozzle capacity and desired pressure droplet size closer to the high e...

Page 18: ...In this case a TT11006 at 3 4 bar will work very well 1 5 1 68 0 2 1 3 1 54 VC XC 92 to 308 69 to 231 55 to 185 46 to 154 2 1 94 0 3 1 7 1 80 VC XC 108 to 360 81 to 270 65 to 216 54 to 180 3 2 37 0 4...

Page 19: ...eJet using part number 97 00067 All repairable parts should be accessible at this point The plunger sub assembly 3 stainless steel spring 6 and O rings 8 9 10 can be replaced without further disassemb...

Page 20: ...88 F C F C 207 to 691 173 to 576 130 to 432 104 to 346 86 to 288 74 to 247 65 to 216 58 to 192 52 to 173 6 3 35 0 7 5 3 3 16 M C 228 to 758 190 to 632 142 to 474 114 to 379 95 to 316 81 to 271 71 to...

Page 21: ...to 12 3 1 to 10 5 3 06 0 6 4 4 2 88 F C F C 21 to 69 14 to 46 10 to 35 8 3 to 28 6 9 to 23 5 2 to 17 4 6 to 15 4 1 to 14 3 5 to 12 6 3 35 0 7 5 3 3 16 M C 23 to 76 15 to 51 11 to 38 9 1 to 30 7 6 to 2...

Page 22: ...5 0 8 to 4 4 0 7 to 3 7 0 5 to 2 8 60 0 98 10 50 0 89 2 4 to 12 1 1 6 to 8 1 1 2 to 6 1 0 9 to 4 8 0 8 to 4 0 0 6 to 3 0 70 1 06 12 58 0 97 2 5 to 13 2 1 7 to 8 8 1 2 to 6 6 1 0 to 5 3 0 8 to 4 4 0 6...

Page 23: ......

Page 24: ...the operator to choose specific droplet sizes that will be used for a particular job The rate controller manages application rate and the DynaJet system uses PWM technology to control system pressure...

Reviews: