Four-Cycle Engine • L-Head • Horizontal Crankshaft • Air-Cooled

181-630-14

CALIFORNIA & US EPA EMISSION CONTROL WARRANTY STATEMENT

The  U.  S.  Environmental  Protection  Agency  (“EPA”),  the
California  Air  Resources  Board  (“CARB”)  and  Tecumseh  Power
Company  are  pleased  to  explain  the  Federal  and  California
Emission  Control  Systems  Warranty  on  your  new  small  off-road
engine.  In  California,  new  1995  and  later  small  off-road  engines
must  be  designed,  built  and  equipped  to  meet  the  State’s
stringent anti-smog standards. In other states, new 1997 and later
model year engines must be designed, built and equipped, at the
time of sale, to meet the U.S. EPA regulations for small non-road
engines.  Tecumseh  Power  Company  will  warrant  the  emission
control  system  on  your  small  off-road  engine  for  the  periods  of
time  listed  below,  provided  there  has  been  no  abuse,  neglect,
unapproved modification, or improper maintenance of your small
off-road engine.

Your  emission  control  system  may  include  parts  such  as  the
carburetor, air cleaner assembly, ignition system, exhaust system,
crankcase  breather  assembly  and,  the  evaporative  control
system.  Also  included  may  be  the  compression  release  system
and other emission-related assemblies.

Where  a  warrantable  condition  exists,  Tecumseh  Power
Company will repair your small off-road engine at no cost to you
for diagnosis, parts and labor.

MANUFACTURER’S EMISSION CONTROL 
SYSTEM WARRANTY COVERAGE

Emission control systems on 1995 and later model year California
small off-road engines are warranted for two years as hereinafter
noted. In other states, 1997 and later model year engines are also
warranted  for  two  years.  If,  during  such  warranty  period,  any
emission-related  part  on  your  engine  is  defective  in  materials  or
workmanship, the part will be repaired or replaced by Tecumseh
Power Company

OWNER’S WARRANTY RESPONSIBILITIES

As  the  small  off-road  engine  owner,  you  are  responsible  for  the
performance of the required maintenance listed in your Operator’s
Manual,  but  Tecumseh  Power  Company  will  not  deny  warranty
solely  due  to  the  lack  of  receipts  or  for  your  failure  to  provide
written  evidence  of  the  performance  of  all  scheduled
maintenance.

As  the  small  off-road  engine  owner,  you  should,  however,  be
aware  that  Tecumseh  Power  Company  may  deny  you  warranty
coverage if your small off-road engine or a part thereof has failed
due  to  abuse,  neglect,  improper  maintenance  or  unapproved
modifications.

You are responsible for presenting your small off-road engine to a
Tecumseh Authorized Service Outlet (any Tecumseh Registered
Service  Dealer,  Tecumseh  Authorized  Service  Distributor  or
Tecumseh Central Warehouse Distributor) as soon as a problem
exists. The warranty repairs should be completed in a reasonable
amount of time, not to exceed 30 days.

Warranty  service  can  be  arranged  by  contacting  either  an
Authorized Tecumseh Servicing Dealer and/or Tecumseh Power
Company,  c/o  Service  Manager,  900  North  Street,  Grafton,  WI
53024-1499.  Telephone  1-262-377-2700  [or  in  USA/Canada  call
1-800-558-5402].

IMPORTANT NOTE

This  warranty  statement  explains  your  rights  and  obligations
under  the  Emission  Control  System  Warranty  (“ECS  Warranty”)
which is provided to you by Tecumseh Power Company pursuant
to  California  law.  Tecumseh  Power  Company  also  provides  to
original  purchasers  of  new  Tecumseh  Power  Company  engines
the  Tecumseh  Power  Company  Limited  Warranties  for  New
Tecumseh  Engines  and  Electronic  Ignition  Modules.  The
Tecumseh  Power  Company  Limited  Warranties  for  New
Tecumseh  Engines  and  Electronic  Ignition  Modules  (“Tecumseh
Power Company Warranty”) are located on the back cover of the
Operator’s  Manual,  enclosed  with  all  new  Tecumseh  Power
Company  engines.  The  ECS  Warranty  applies  only  to  the
emission  control  system  of  your  new  engine.  To  the  extent  that
there is any conflict in terms between the ECS Warranty and the
Tecumseh  Power  Company  Warranty,  the  ECS  Warranty  shall
apply except in any circumstances in which the Tecumseh Power
Company  Warranty  may  provide  a  longer  warranty  period.  Both
the ECS Warranty and the Tecumseh Power Company Warranty
describe important rights and obligations with respect to your new
engine.

Warranty  service  can  only  be  performed  by  a  Tecumseh  Power
Company Authorized Servicing Dealer. At the time of requesting
warranty service, evidence must be presented of the date of sale
to the original purchaser. The purchaser shall pay any charges for
making  service  calls  and/or  for  transporting  the  products  to  and
from  the  place  where  the  inspection  and/or  warranty  work  is
performed. The purchaser shall be responsible for any damage or
loss incurred in connection with the transportation of any engine
or  any  part(s)  thereof  submitted  for  inspection  and/or  warranty
work.

If you have any questions regarding your warranty rights and 
responsibilities, you should contact Tecumseh Power Company at 
1-262-377-2700 or in USA/Canada call 1-800-558-5402.

Revised July, 2005

IMPORTANT!

The emission Regulations may be different for your country. The emissions Control Warranty Statement is only applicable 
to engines with an emissions compliance statement and decal that references “Emissions Regulations”.

Summary of Contents for LH358EA

Page 1: ...ine and Short Term Storage 12 VII Maintenance 12 VIII Transporting Your Engine 15 IX Storing your Engine 15 X Preventing Forest Brush and Grass Fires 17 XI Maintenance Intervals 18 California US EPA Emission Control Warranty Statement 20 Emission Control System Warranty 21 XII Warranty Information 22 181 630 14 English 12 01 06 Register Your Tecumseh Engine Maintenance Tips Parts Look Up System Gr...

Page 2: ...rator s Manual Follow these basic rules for your personal safety Keep this manual handy at all times for future reference Read it carefully and familiarize yourself with operating maintenance components and safety instructions Notice Regarding Emissions NOTE Engines which are certified to comply with California and U S EPA emission regulations for SORE Small Off Road Equipment are certified to ope...

Page 3: ... container to store and dispense fuel Tecumseh recommends purchasing gasoline in containers with a capacity of 2 5 gallons or less Small containers are easier to handle and help eliminate spillage during refueling DO NOT pour fuel from engine or siphon fuel by mouth To empty fuel tank see I Draining Fuel instructions on page 16 C Adult Supervision of Operation Refueling and Maintenance The manufac...

Page 4: ...accidental starting when working on equipment always Disconnect spark plug wire and keep it away from spark plug See Figure 3 Keep the disconnected spark plug wire securely away from metal parts where arcing could occur Attach the spark plug wire to the grounding post if provided See Figure 4 Disconnect battery at negative terminal first if engine is equipped with an electric starter Turn off all ...

Page 5: ...ded for individuals who have had adequate training experience and who practice proper tool usage Service procedures should be clearly understood and practiced when servicing Tecumseh Engines Order as part no 692509 for LH Models Tecumseh manufactures and is responsible only for the engine used on this power equipment If repair or service is needed for anything other than the engine contact the ser...

Page 6: ...listed in the Operator s Manuals will not be considered warranty IV Before Starting Your Engine A Checking Oil Level To avoid engine damage it is important to Check oil level before each use and every 5 operating hours when engine is warm Check oil level more frequently during engine break in Keep oil level between FULL and ADD marks on dipstick See Figure 7 Be sure oil fill cap is tightened secur...

Page 7: ... 9 D Low Oil Shutdown Switch Some engines are equipped with an optional Low Oil Shutdown Switch This is a lighted rocker switch that is connected to a float switch in the engine crankcase When oil level drops below a predetermined level the float switch cuts off current to the spark plug and the engine stops running Oil must be added to the engine to bring the oil to the proper level before the en...

Page 8: ...highly flammable and can explode Fuel vapors can spread and be ignited by a spark or flame many feet away from engine To prevent injury or death from fuel fires follow these instructions 1 Stop engine and allow it to cool before refueling 2 Be sure engine is outdoors and in a well ventilated area 3 Clean area around fuel fill cap and remove fuel fill cap See Figure 11 4 Using an approved red GASOL...

Page 9: ...ot equipped with a CLIMATE GUARD air cleaner a CLIMATE GUARD Conversion Kit is available at any Authorized Tecumseh Servicing Dealer See Figure 15 If the engine is equipped with a CLIMATE GUARD no changes need to be made when changing from summer to winter operation See Figure 16 I Winter Application In temperatures below 32 F 0 C the inlet air scoop should be pointed directly at the muffler II Su...

Page 10: ...ectric Starters instructions below If you have a manual recoil starter see B Engines with Recoil Starters instructions on page 10 A Engines with Electric Starters 1 To avoid carbon monoxide poisoning make sure engine is outdoors in a well ventilated area 2 Move engine Stop Switch or Low Oil Shutdown Switch to ON if present see equipment manufacturer s instructions See Figures 17 and 18 3 Be sure f...

Page 11: ...ntrol to NO CHOKE position 7 If engine dies after Choke Control is to moved to NO CHOKE position repeat steps 2 thru 6 to restart engine 8 If engine fires but does not continue to run move Choke Control to NO CHOKE position and start engine 9 If engine fails to start after 3 attempts in the NO CHOKE position move Choke Control to FULL CHOKE position and start engine 10 If engine does not start aft...

Page 12: ...itches are on See Figure 14 on page 7 4 Move Engine Speed Control to FAST position and set Choke Control to FULL position see equipment man ufacturer s instructions See Figures 25 thru 28 NOTE If restarting a warm engine after a short shutdown move Engine Speed Control to FAST position and Choke Control to NO CHOKE position Figure 23 Engine Stop Switch Figure 24 Low Oil Shutdown Switch Figure 25 T...

Page 13: ...ontrol is moved to NO CHOKE position a Momentarily move Choke Control back to FULL CHOKE position b Next move Choke Control to 1 2 CHOKE position until engine runs smoothly c Finally move Choke Control to NO CHOKE position 8 If engine dies after Choke Control is to moved to NO CHOKE position repeat steps 2 thru 7 to restart engine 9 If engine fires but does not continue to run move Choke Control t...

Page 14: ...efore each use and every 5 operating hours See A Checking Oil Level instructions on page 4 Change oil after first 2 operating hours and every 25 operating hours thereafter more often if operated in extremely dusty or dirty conditions Engine should still be warm but not hot from recent use 1 Be sure you find the correct drain plug location if pro vided See Figure 30 2 Disconnect spark plug wire and...

Page 15: ...air cleaner on your engine Your engine will be equipped with one of the following air cleaners Type A or B Follow instructions for the air cleaner type that resembles your model See Figure 33 and Figure 34 NOTE Contact your Authorized Tecumseh Servicing Dealer for Tecumseh Air Cleaner I Servicing Foam Filters Clean foam pre filter every 3 months or every 25 operating hours Clean daily if used in e...

Page 16: ...your equipment manufacturer s instructions and an Authorized Tecumseh Servicing Dealer F Carburetor If you think your carburetor needs adjusting see your nearest Authorized Tecumseh Servicing Dealer Engine performance should not be affected at altitudes up to 7 000 feet 2 134 meters For operation at higher elevations contact your Authorized Tecumseh Servicing Dealer G Engine Speed To avoid serious...

Page 17: ...the blower housing In addition remove grass clippings dirt and debris from the following areas Cooling fins Air intake screen Levers Linkage Guards Carburetor Head Removing debris will facilitate adequate cooling correct engine speed and reduce the risk of fire I Fuel Storage NEVER store engine with fuel in fuel tank inside a building with potential sources of ignition such as hot water and space ...

Page 18: ...bilizer you can empty the fuel tank as described under I Draining Fuel instructions See B Extended Storage instructions B Extended Storage I Draining Fuel NOTES Clean debris from engine before draining fuel from carburetor See I Clean Engine instructions on page 15 If you have prepared your fuel for short term storage it is not necessary to drain fuel that contains stabilizer from your carburetor ...

Page 19: ...he engine for one to two seconds 7 Turn ignition switch key to OFF position Repeat Step 6 and Step 7 This will distribute oil throughout the cyl inder to prevent corrosion during storage 8 Remove rag covering spark plug hole and install spark plug 9 Carefully disconnect spark plug wire from grounding post if provided See Figure 36 NOTE Connect spark plug wire before attempting to start engine once...

Page 20: ...___Owner Dealer Date_______________Owner Dealer Date_______________Owner Dealer Date_______________Owner Dealer Date_______________Owner Dealer Date_______________Owner Dealer Date_______________Owner Dealer Date_______________Owner Dealer Date_______________Owner Dealer Date_______________Owner Dealer Date_______________Owner Dealer Date_______________Owner Dealer Date_______________Owner Dealer ...

Page 21: ..._____________Owner Dealer Date_______________Owner Dealer Date_______________Owner Dealer Date_______________Owner Dealer Date_______________Owner Dealer Every 200 Hours or Seasonally Scheduled Maintenance 1 Replace Spark Plug Date_______________Owner Dealer Date_______________Owner Dealer Date_______________Owner Dealer Date_______________Owner Dealer Date_______________Owner Dealer Date_________...

Page 22: ...d engine to a Tecumseh Authorized Service Outlet any Tecumseh Registered Service Dealer Tecumseh Authorized Service Distributor or Tecumseh Central Warehouse Distributor as soon as a problem exists The warranty repairs should be completed in a reasonable amount of time not to exceed 30 days Warranty service can be arranged by contacting either an Authorized Tecumseh Servicing Dealer and or Tecumse...

Page 23: ...placement the part shall be repaired or replaced by Tecumseh Power Company according to Subsection 4 below Any such emissions related part repaired or replaced under the ECS Warranty shall be warranted for the remainder of the ECS Warranty Period prior to the first scheduled replacement point for such emissions related part 4 Repair or replacement of any warranted emissions related part under this...

Page 24: ...purposes of this warranty policy consumer use shall mean consumer s personal residential household use by the original retail purchaser 5 For purposes of this warranty policy commercial use shall mean all other uses including use for commercial income producing or rental purposes 6 The engine warranty category of your engine can be determined by review of the engine model number on the Important E...