![Tectro TBH 558 User Manual Download Page 128](http://html1.mh-extra.com/html/tectro/tbh-558/tbh-558_user-manual_1073086128.webp)
128
Stove goes
out. The alert
shown is “AlAr
dEp” and one
or both of the
LEDs ALF and
ALC on the
control panel
are lit.
Pressure sensor/switch is
defective
Replace the pressure switch. Only to be
done by a Tectro-approved technician
The exhaust/flue/chimney
is blocked
Have the exhaust/flue/chimney cleaned im-
mediately by an approved chimney sweep.
Contact an approved chimney sweep.
Electronic printed circuit
board is defective.
Replace the electronic printed circuit
board. Only to be done by a Tectro-ap-
proved technician
Excessive flue length
Consult a flue specialist to check whether
the flue complies with the law. Consult
a Tectro-approved technician to check
whether the flue is suitable for the stove.
Unfavourable weather
conditions
Strong winds can cause negative pressure
in the flue. Check and restart the stove.
Stove is overheating
Room temperature too low. Open doors
to other rooms. If the problem persists,
contact a Tectro-approved technician.
The safety thermostat on the stove has
been triggered. Let the stove cool down,
then reset the safety thermostat by re-
moving the protective cap (figure 26) and
pressing the reset button (figure 27).
The room air recircula-
tion blower is defective
Replace the blower. Only to be done by a
Tectro-approved technician
Temporary power outage
A power cut when the stove is in opera-
tion can cause the interior to overheat.
Allow the heater to cool down and restart
it.
Safety thermostat is
defective
Replace the safety thermostat. Only to be
done by a Tectro-approved technician
Stove goes
out. “AlAr
Sond” is
shown in the
display
Flue gas temperature
sensor is defective.
Replace the sensor. Only to be done by a
Tectro-approved technician
The wiring to the flue
gas sensor is loose.
Fix the wiring. Only to be done by a Tec-
tro-approved technician
Display shows
“Cool Fire”
The stove has been
switched off manually,
by the timer mode or the
save mode. The stove is
in cooling down phase.
This is not an error; the cooling down
phase stops automatically when the stove
has cooled down sufficiently.
Power failure
After the electricity supply has been re-
stored, the stove will start in the cooling
down phase. The stove can then be started
up again.
4
Summary of Contents for TBH 558
Page 67: ...67 5...
Page 99: ...99 3...
Page 100: ...100 3 SEULEMENT POUR LA BELGIQUE...
Page 101: ...101 3 SEULEMENT POUR LA BELGIQUE...
Page 163: ...163...
Page 195: ...195 1...
Page 196: ...196 ENKEL VAN TOEPASSING VOOR BELGI 1...
Page 197: ...197 ENKEL VAN TOEPASSING VOOR BELGI 1...
Page 233: ...233 9...
Page 259: ...259 y...
Page 260: ...260 1 4 5...
Page 261: ...261 6 7 8...
Page 262: ...262 9 10 11...
Page 263: ...263 12 13 14...
Page 264: ...264 15 16 17...
Page 265: ...265 18 19 20...
Page 266: ...266 21 22 23...
Page 267: ...267 24 25 26...
Page 268: ...268 27...
Page 269: ...269...
Page 270: ...270...
Page 271: ...271...