![Tectro CL 1630 Operating Manual Download Page 54](http://html1.mh-extra.com/html/tectro/cl-1630/cl-1630_operating-manual_1073055054.webp)
54
refrigerants in recovery units and especially not in cylinders.
lf compressors or compressor oils are to be removed, ensure that they have been
evacuated to an acceptable level to make certain that flammable refrigerant does
not remain within the lubricant. The evacuation process shall be carried out prior to
returning the compressor to the suppliers. Only electric healing to the compressor
body shall be employed to accelerate this process. When oil is drained from a system,
il shall be carried out safely.
B
INSTALLATION
G
WARNING
Before using the air conditioner it should be left in an upright position
for at least 2 hours.
This unit is portable and can easily be moved from one room to another. In doing
so keep this in mind:
Ensure that the unit is positioned upright and on a level surface.
Do not operate the unit inside the bathroom, shower, or in any other very
humid environment.
Please keep a distance of 50 cm between the unit and the wall or other
objects to ensure proper air circulation.
One end of the hose
J
must be attached to the air outlet
7
at the back of
the unit.
Ensure that the window air outlet
9
has a free flow outside. Close the
window or door as much as possible to prevent outside air from entering the
room.
G
IMPORTANT
The flexible exhaust hose
9
should be less than 1m during operation,
which provides the best performance. This length has been designed
especially according to the specifications of the air conditioner. Do not
use an extension or exchange for a different hose as that may lead to
malfunctioning. The exhaust air must flow freely, any blockage can lead
to overheating of the air conditioner. Take care to prevent any bow or
bend in the exhaust hose.
C
OPERATION
1
2
3
4
5
6
7
8
9
J
K
4
Summary of Contents for CL 1630
Page 63: ...63 4...
Page 83: ...83 1...