UNIVERSAL BAR DIAM.80 

 

 

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

   

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 FANS SAFETY REGULATIONS 

            ATTENTION: 

 

Read the manual carefully before starting to use the fans. Keep the instructions for future reference. 
 

 
 
Do not touch/disassemble the bar or the fans while they are in operation: RISK OF INJURY. 

The  product  must  be  installed  in  a  place  with  access  limited  to  qualified  personnel  only.  Any  work  on  the  equipment 
must be entrusted to a qualified engineer. 
 

 
Do not touch the motor or the power cables. Contact with a voltage of 120/230 Vac can be fatal. To reduce 
the risk of electric shock, do not dismantle or modify the fan motor for any reason. 

Before  connecting  the  system  to  the  power  supply,  make  sure  that  all  the  connections  are  correct. 

Always 

disconnect the fan from the power supply before performing any type of maintenance. 
 

 
Never touch the motor, danger of burns: RISK OF INJURY. 

 
 

POWER SUPPLY 

Before using it, always make sure the power cable is not damaged, knotted or pinched. 
Do not tamper with the power cable. Never disconnect the unit by pulling the cable and avoid touching the pins. Do not 
carry  out  any  operations  of  connecting/disconnecting  with  wet  hands.  To  disconnect  the  system,  do  not  use  objects 
such as levers. Immediately disconnect the power supply if it is evident that the system is giving off a smell of burning or 
smoke and contact the Tecsystem technical assistance. 

 

LIQUIDS 

Do  not  expose  the  product  to  dripping  or  splashing  liquids.  Do  not  place  in  places  with  humidity  over  90%  and  never 
touch with wet or damp hands. 

 

CLEANING 

Before cleaning the fan, always disconnect the power cord.  To avoid malfunctions only use compressed air to remove 
dust and dirt. Do not use lubricants or greases of any kind. 

 

OBJECTS 

Never insert objects into the air inlet or outlet If this happens disconnect the fan and contact a technician. 

 
USE RESERVED TO QUALIFIED PERSONNEL 

The  purchased  product  is  a  sophisticated  electro-mechanical  device  that  must  never  be  used  by  non-qualified 
personnel. Any work must be carried out by a specialist engineer. 

 

ACCESSORIES 

Do  not  use  non-original  accessories  or  spare  parts  as this  could cause  damage  to the  fan  and  endanger  the  user.  In 
case of faults, contact technical assistance. 

 

LOCATION 

Install the fan indoors in a place protected from w

ater splashes and from the sun’s rays. Do not place near heat sources 

exceeding  the  parameters  stated  in  this  manual.  Place  horizontally  and  on  stable  surfaces.  The  product  must  be 
installed in a place with access limited to qualified personnel only. 

 

REPAIRS 

Do  not  repair or  modify the  fan  yourself. For  any  fault,  always  use  qualified  personnel.  Opening  or tampering  with the 
fan automatically invalidates the warranty. 

 

PRODUCTION 

The  date  and  the  production  batch  of  the  product  are  shown  on  a  label  placed  on  the  fan. 

Removal  of  the  label 

automatically invalidates the warranty. 
 
TECHNICAL OR REPORTING INFORMATION 

 

Mail

[email protected]

 - tel.:+39 024581861

 

 

Summary of Contents for TG180

Page 1: ...rtified quality system http www tecsystem it R 1 1 18 02 22 Translations of the original instructions TECSYSTEM S r l 20094 Corsico MI Tel 39 024581861 Fax 39 0248600783 UNIVERSAL BAR INSTRUCTION MANU...

Page 2: ...antage of all its functions ATTENTION THIS MANUAL IS VALID AND COMPLETE FOR THE PRODUCT UNIVERSAL BAR DIAM 80 PAGE 1 SAFETY REGULATIONS 3 2 BAR TECHNICAL SPECIFICATIONS 4 3 FAN PARAMETERS 4 UNIVERSAL...

Page 3: ...Do not expose the product to dripping or splashing liquids Do not place in places with humidity over 90 and never touch with wet or damp hands CLEANING Before cleaning the fan always disconnect the p...

Page 4: ...ATIONS 120Vac 60Hz UL MODEL TG180 TG360 TG500 POWER SUPPLY 120Vac 60Hz CURRENT 1 24A 1 65A 1 88A POWER 132W 188W 210W TECHNICAL SPECIFICATIONS MODEL 1200 1800 3600 BAR LENGTH 1400mm 1800mm 2300mm NUMB...

Page 5: ...4 REV 0 The bar consists of two side profiles 645mm a central profile length 1400mm The two side profiles have been designed to slide inside the central profile in order to guarantee an extension from...

Page 6: ...screws and detach the cables bar initial position 1200 and if necessary slide the side profiles up to the desired dimension 1800 3600 The M4 locking screws are used to fasten the bar at the desired le...

Page 7: ...ired position Place the fans on the bar and centre each individual fan with the U V W reference column 1MN0207 REV 0 U V W 1MN0206 8 REV 0 Appropriately position the wiring for the fans M1 M2 M3 Place...

Page 8: ...ans on the bar using the dedicated holes on the back do not modify the fixing holes of the fan When handling the fans avoid deforming the impeller fins Never modify the positioning of the motor If the...

Page 9: ...conductor MAX 4mm preferably with a dedicated ferrule inside the reference terminal with the respective marking L EARTH or N Terminate the connection by inserting the other L EARTH N conductors Apply...

Page 10: ...OTE failure to comply with the assembly notes and possible use in extreme environmental conditions such as lengthy periods of standstill high humidity high temperatures excessive dustiness and excessi...

Page 11: ...11 UNIVERSAL BAR DIAM 80 FAN DIMENSIONS TG180 1VN0006 TG500 1VN0016 TG360 1VN0010 1MN0230 REV 0 1MN0229 REV 0 1MN0231 REV 0...

Page 12: ...12 UNIVERSAL BAR DIAM 80 NOTE dimensional tolerance of bar drawings 10mm 1MN0243 REV 0 BAR DIMENSIONS 1MN0235 REV 0 1MN0244 REV 0 BAR 1800 BAR 3600 BAR 1200...

Page 13: ...roducts have on the environment and asks its customers active support in the correct and environmentally friendly disposal of its devices TECHNICAL INFORMATION ufficiotecnico tecsystem it COMMERCIAL I...

Reviews: