10 

UNIVERSAL BAR DIAM.80

 

 

 

 

 

 

 

Should it be necessary, modify the wiring or disconnect the connectors. 

 

 

Using  a  2.5mm  slotted  screwdriver,  press  the  PUSH  spring 
under  the  connector.  Move  the  socket  connector  slightly  left 
and right and pull.

 

Using  a  2.5mm  slotted  screwdriver,  press  the  internal 
spring of the connector. Pull out the conductor. 

 

Insert the socket con assembled casing (1) inside the plug connector (2) arranged on the bar. 

 

POWER SUPPLY 
 

Before connecting the ventilation bar to the power supply, always check that: the voltage and frequency parameters shown 
on the fan label correspond to the values available on the system.

 

 

 

 

 

ENVIRONMENTAL CONDITIONS OF USE 
 

 

Absence of fine dusts. 
Absence of flammable or corrosive gases. 
Relative humidity:90% non-condensing (for short periods). 
N.B.: maximum temperature as prescribed by the IEC 60076-11 standard. 
Installation in a marine environment is not recommended, unless after specific treatment of the metal parts. 

 

 
NOTE: failure to comply with the assembly notes and possible use in extreme environmental conditions such as: 
lengthy periods of standstill, high humidity, high temperatures, excessive dustiness and excessive vibrations, can 
anticipate deterioration of the mechanical parts of the fans.
 

MAINTENANCE 
 

In order to maintain the efficiency of the fans, clean them periodically (every 6 months) using only compressed air. Do not 
use lubricants or greases of any kind. 

 

Any  prolonged  standstill  of  the  fan  could  cause  malfunctions.  Installation  of  the  fans  combined  with  the  Tecsystem 
thermometric  control  units  avoids  any  prolonged  shutdowns.  By  enabling  the  HFN  function  present  in  the  Tecsystem 
control units, it is possible to program fan activation cycles from 1 to 200 hours, recommended setting every 24 hours (for 
further information on the HFN function, check the manual of the control unit purchased). 

 
NOTE:  Periodic  maintenance  and  activation  of  the  HFN  will  allow  you  to  extend  the  efficiency  of  the  fans. 
Maintenance operations on the fans must be scheduled according to the environmental conditions in which they 
operate. 

PUSH 

1MN0241 REV.0 
 

1MN0241 REV.0 
 

1MN0242 REV.0 
 

Summary of Contents for TG180

Page 1: ...rtified quality system http www tecsystem it R 1 1 18 02 22 Translations of the original instructions TECSYSTEM S r l 20094 Corsico MI Tel 39 024581861 Fax 39 0248600783 UNIVERSAL BAR INSTRUCTION MANU...

Page 2: ...antage of all its functions ATTENTION THIS MANUAL IS VALID AND COMPLETE FOR THE PRODUCT UNIVERSAL BAR DIAM 80 PAGE 1 SAFETY REGULATIONS 3 2 BAR TECHNICAL SPECIFICATIONS 4 3 FAN PARAMETERS 4 UNIVERSAL...

Page 3: ...Do not expose the product to dripping or splashing liquids Do not place in places with humidity over 90 and never touch with wet or damp hands CLEANING Before cleaning the fan always disconnect the p...

Page 4: ...ATIONS 120Vac 60Hz UL MODEL TG180 TG360 TG500 POWER SUPPLY 120Vac 60Hz CURRENT 1 24A 1 65A 1 88A POWER 132W 188W 210W TECHNICAL SPECIFICATIONS MODEL 1200 1800 3600 BAR LENGTH 1400mm 1800mm 2300mm NUMB...

Page 5: ...4 REV 0 The bar consists of two side profiles 645mm a central profile length 1400mm The two side profiles have been designed to slide inside the central profile in order to guarantee an extension from...

Page 6: ...screws and detach the cables bar initial position 1200 and if necessary slide the side profiles up to the desired dimension 1800 3600 The M4 locking screws are used to fasten the bar at the desired le...

Page 7: ...ired position Place the fans on the bar and centre each individual fan with the U V W reference column 1MN0207 REV 0 U V W 1MN0206 8 REV 0 Appropriately position the wiring for the fans M1 M2 M3 Place...

Page 8: ...ans on the bar using the dedicated holes on the back do not modify the fixing holes of the fan When handling the fans avoid deforming the impeller fins Never modify the positioning of the motor If the...

Page 9: ...conductor MAX 4mm preferably with a dedicated ferrule inside the reference terminal with the respective marking L EARTH or N Terminate the connection by inserting the other L EARTH N conductors Apply...

Page 10: ...OTE failure to comply with the assembly notes and possible use in extreme environmental conditions such as lengthy periods of standstill high humidity high temperatures excessive dustiness and excessi...

Page 11: ...11 UNIVERSAL BAR DIAM 80 FAN DIMENSIONS TG180 1VN0006 TG500 1VN0016 TG360 1VN0010 1MN0230 REV 0 1MN0229 REV 0 1MN0231 REV 0...

Page 12: ...12 UNIVERSAL BAR DIAM 80 NOTE dimensional tolerance of bar drawings 10mm 1MN0243 REV 0 BAR DIMENSIONS 1MN0235 REV 0 1MN0244 REV 0 BAR 1800 BAR 3600 BAR 1200...

Page 13: ...roducts have on the environment and asks its customers active support in the correct and environmentally friendly disposal of its devices TECHNICAL INFORMATION ufficiotecnico tecsystem it COMMERCIAL I...

Reviews: