TECHNICAL SPECIFICATIONS
NT935BH-D
POWER SUPPLY
Supply rated values
85-260 Vac-Vdc
50/60HZ
Vdc with invertible polarities
●
INPUTS
4 inputs for three-wire Pt100 RTD sensors (max section 1.5mm²)
●
Connections on removable terminal boards
●
Input channels protected against electromagnetic interference
●
Thermoresistances cable compensations
500 m (1 mm²)
OUTPUTS
2 alarm relays (ALARM AND TRIP) SPDT
●
1 sensor or operating failure (FAULT) relay SPST
●
1 ventilation management relay SPST FAN 2
●
Output relays with 10A-250Vac-
res COSФ=1 contacts.
●
TRBH output FAN1 control bars B1 - B2
●
RS485 output Modbus RTU
●
DIMENSIONS
100x100 mm
– din43700-prof .131mm (including terminal block)
Hole 92 x 92 mm
TESTS AND PERFORMANCE
Construction in compliance with CE regulations
●
Protection from electrical interference EN 61000-4-4
●
Dielectric strength 1500 Vac for a min. between output relays and sensors, relay and
power supply, power supply and sensors
●
Accuracy ±1% full scale value, ±1 digit
●
Ambient operating temperature from
–20°C to +60°C
●
Humidity 90% non-condensing
●
Polycarbonate frontal film IP65
●
Housing NORYL 94 _V0
●
Absorption 7.5VA
●