10. Setpoints
The instrument is capable of working with two internal setpoints. The status of these
setpoints is displayed on the LCD. Each setpoint is associated with a physical output
driver but it may also be simply used as an indicator.
Refer to SET.PTS (Setpoint Settings) page 38 for details on settings.
10.1. Setpoint Connection
Refer to Auxiliary Connection page 10 for the method of connection of the external
output drivers.
10.2. Setpoint Operation
The SET.PTS:SETPt.1/2 settings allow output 1 and output 2 to be independently
configured as:
Off
On
an overload setpoint,
an underload setpoint,
output on motion,
output on zero,
output when net displayed,
output on error,
output when an error occurs.
The SET.PTS:SRC.1/2 settings allow the gross weight, displayed weight, or net
weight to be chosen as the source for the setpoint operation. This allows the
overload and underload limits to be linked to gross weights always or alternatively to
be linked to the current displayed weights, or the net weight.
The SET.PTS:TARG.1/2 values set the values for the overload and underload
limits.
1 Annunciator is displayed in the lower section of the display when the output 1 is
active.
2 Annunciator is displayed in the lower section of the display when the output 1 is
active.