Maintenance
Operation only allowed to qualified person, damages due to
unprofessional operation or remove of any parts inside will
not be considered in warranty service. There are no service-
able parts inside the device or package, service only leaves to
authorized dealers.
Never allow the optical components contact with oil, fat or
any other liquid.
A regular clearance of the device is needed for long-term us-
age, this is very helpful to maintain the lifetime and bright-
ness need to use a soft and lint-free cloth to clean the optical
system, fan and air flowing tunnel.
Trouble Shooting
Problems
Possible reasons
Checking or solutions
Device not
power up
Powercon or power cable damaged
Change a good power cable to try
Faulty power supply
Replace new power supply
Pan/Tilt error
or vibrate
Faulty Pan/Tilt PCB
Replace PT001 PCB
Faulty opto sensor
Replace opto sensor OP001
Cable loosen
Check the cable connect to OP001
LED off
Temperature protection
Check the temperature from menu
Fan not working
Check the fan speed info from menu
Faulty LED
Replace new LED
Dimmer and strobe set at 0
Set dimmer and strobe channel at 255
Faulty power supply
Replace new power supply
Device not
response to
DMX
Faulty communication IC
Replace the IC with back-up one in the display PCB
Faulty display PCB
Replace new display PCB
Wrong DMX addressing
Check the address and setting
Faulty DMX cable
Change to a good DMX cable
Replacement of the fuse
Need to replace with same type and rating, which originally
installed in the device.
Step One: Unplug power cable from main power.
Step Two: Unscrew the fuse holder out of the housing with
a screwdriver.
Step Three: Remove the broken fuse and replace with an ex-
act same type of new fuse.
Step Four: Insert the fuse holder back to the housing and
screw tight and reconnect power.