Trouble Shooting
Problems
Possible reasons
Checking or solutions
Device not power up
Powercon or power cable
damaged
Change a good power cable to try
Faulty power supply
Replace new power supply
Pan/Tilt error or vibrate
Faulty Pan/Tilt PCB
Replace PT001 PCB
Faulty opto sensor
Replace opto sensor OP001
Cable loosen
Check the cable connect to OP001
Lamp off
Temperature protection
Check the temperature from menu
Fan not working
Check the fan speed info from menu
Faulty Lamp
Replace new Lamp
Dimmer and strobe set at 0
Set dimmer and strobe channel at 255
Faulty power supply
Replace new power supply
Device not response to
DMX
Faulty communication IC
Replace the IC with back-up one in the
display PCB
Faulty display PCB
Replace new display PCB
Wrong DMX addressing
Check the address and setting
Faulty DMX cable
Change to a good DMX cable
Replacement of the fuse
Need to replace with same type and rating, which originally
installed in the device.
•
Step One: Unplug power cable from main power.
•
Step Two: Unscrew the fuse holder out of the housing
with a screwdriver.
•
Step Three: Remove the broken fuse and replace with an
exact same type of new fuse.
•
Step Four: Insert the fuse holder back to the housing and
screw tight and reconnect power.