background image

FLATSIX - LED PAR LIGhT

ENGLISH VERSION

p. 4

Safety Instruction

  

• 

Please conserve this manual as operation guidance. If 
you sell this product to other user, please make sure that 
they also receive this user manual. 

• 

Always make sure that you are connecting to the proper 
voltage and that the line voltage you are connecting to is 
not higher than that stated on the decal or rear panel of 
the fixture. 

•  The fixture is intended to indoor use only. To prevent 

risk of fire or shock, do not expose fixture to rain or 
moisture.  Make  sure  there  are  no  flammable,  explo-
sive or corrosive materials surrounded in 0.5 meter 
while operating. 

• 

The unit must be installed in a location with adequate 
ventilation, at least 50CM away from adjacent surfaces. 
Be sure that no ventilation slots are blocked. 

• 

Do not operate at ambient temperatures higher than 
104º(40º). 

• 

Safe wire should be used to install machine. Bearing of 
safe wire should be 3 times of the machine weight. Com-
plimentary signal cable transmits signals to 20 unit fix-
tures at most. Signal amplifier is a must to connect more 
fixtures. Sectional area of complimentary power cable is 
1m2. In daisy chain model, it allows to connect to 4 fix-
tures at most. 

• 

Always disconnect from the power source before servic-
ing or replacing fuse/lamp and be sure to replace with 
same fuse/lamp size and type. Cut off power before mov-
ing, repairing and cleaning the machine.

• 

Secure fixture using a safety chain and carrying handles. 
Never carry the fixture by its cord.

• 

In case of failure or misfunction occurred, stop using the 
unit immediately. 

• 

Repairs carried out by unskilled people can lead to dam-
age or malfunction. Buy the same spare parts/compo-
nents from manufacturer directly. 

• 

To avoid electric shock, all fixtures must be connected 
to circuits with a suitable ground. Make sure the power 
cord is never crimped or damaged. Do not power on and 
power off the fixture in a short time. For your safety, do 
not touch fixture when running. 

• 

When use DMX controller, please make sure that there 
is no interference sources(e.g. intercom, high frequency 
radio waves and radiation source)

Caution!

There are no user serviceable parts inside the unit. Do not 
open the housing or attempt any repairs yourself. In the un-
likely event your unit may require service, please contact 
your local distribution or after-sale service center.

For your safe, please read this user manual carefully before turn on the fixture. This machine should be operated by 
qualified engineer.

Summary of Contents for FLATSIX

Page 1: ...LED Par Light USER MANUAL MANUAL DE USUARIO PLEASE READ THE INSTRUCTIONS CAREFULLY BEFORE USE POR FAVOR LEA LAS INSTRUCCIÓNES ANTES DE USAR FLATSIX ...

Page 2: ...npacking Safety Instruction Section 2 Set Up Installation Controlling Board Machine Connection Section 3 Troubleshooting Troubleshooting Section 4 Reference Control Menu DMX Protocol Specification FLATSIX LED Par Light ENGLISH VERSION p 2 ...

Page 3: ... range Carefully unpack the box and check the contents to ensure that all parts are pres ent and in good conditions If anything looks as if it has been damaged in transit notify the shipper immediately and keep the packing material for inspection Again please save the carton and all packing materials If a fixture must be returned to manufacturer it is important that the fixture be returned in the ...

Page 4: ...hain model it allows to connect to 4 fix tures at most Always disconnect from the power source before servic ing or replacing fuse lamp and be sure to replace with same fuse lamp size and type Cut off power before mov ing repairing and cleaning the machine Secure fixture using a safety chain and carrying handles Never carry the fixture by its cord In case of failure or misfunction occurred stop us...

Page 5: ... technician Controlling Board Front display panel MENU switch menu function UP On function page up On numerical value increase value DOWN On function page down On numerical value reduce value ENTER Settle selected function and value 1 Display Display menu and selected function 2 Button 3 DMX signal input Control model by DMX signal please use 3pin XLR signal cable 4 DMX Signal output Transfer DMX ...

Page 6: ...lems with erratic fixture behavior especially over long signal cable runs a terminator may help improve performance To build your own DMX Terminator Obtain a 120 ohm 1 4 watt resistor and wire it between pins 2 3 of the last fixture They are also readily available from specialty retailers Maximum 8 PCS fixtures connected by Daisy chain connection Master Slave control model Set up one fixture as Ma...

Page 7: ...n cables Conflict between tracking and vec tor control Eliminate scene cross fade on controller Data link not terminated Insert termination plug in output of last fixture Defective fixture or 2 devices trans mitting on link Bypass fixtures one at a time until normal operation is regained unplug both connectors and connect them directly together Colors cannot be mixed Random color mixing is on Turn...

Page 8: ... 8 C C000 C255 color shade speed from slow to fast 9 J J000 J255 color skip speed from slow to fast 10 S S000 S255 sound active speed from slow to fast 11 d DMX11 channel mode should link to DMX controller 12 d DMX7 channel mode should link to DMX controller CH Function Description CH1 Dimmer RGBAUVW linear dimmer from dark to bright CH2 R Dimmer Red linear dimmer from dark to bright CH3 G Dimmer ...

Page 9: ... ColorMix Color mixing adjusting CH10 Stand alone 0 60 shade 61 120 skip 121 180 shade skip 181 240 sound active flash 241 255 skip by sound CH11 Stand alone Speed DMX 9 stand alone speed and sound active speed adjusting from slow to fast DMX Protocol 11CH Specification Voltage AC100V 240V Frequency 50 60Hz Rated Power 100W LED 10WX7 RGBWA UV 6IN1 Control DMX512 Beam angle 25 40 option Channel 11 ...

Page 10: ...ta en funcionamiento Desembalaje Instrucciones de seguridad Sección 2 Configuración Instalación Panel de control Conexiones Sección 3 Resolución de problemas Resolución de problemas Sección 4 Referencias Menú de control Protocolo DMX Especificaciones técnicas ...

Page 11: ...ro producto FLATSIX Desembale cuidadosamente la unidad Verifique que todas las piezas del producto se encuentren presentes y en óptimas condiciones Si algún insumo se encontrase dañado como consecuencia del transporte deberá contactar inmediatamente al trans portista y conservar los materiales de embalaje para su in spección Conserve la caja y todos los insumos de embalaje ya que deberá enviarlos ...

Page 12: ...idad o reemplazar el fusible o la lámpara desenchufe el equipo Asegúrese de utilizar fus ibles o lámparas de repuesto del mismo tipo y tamaño Apague la unidad antes de trasladarla o de realizar tar eas de reparación o limpieza Asegure la unidad utilizando una cadena de seguridad y las manijas de transporte Nunca traslade el equipo uti lizando el cable Si la unidad presenta fallas o no funciona cor...

Page 13: ...ada 2 Teclas 3 Entrada de señal DMX Controle la unidad por señal DMX Utilice un cable de señal XLR de 3 pins 4 Salida de señal DMX Transfiera la señal DMX a la siguiente unidad Utilice un cable de señal XLR de 3 pins 5 Salida de alimentación Utilice esta salida para conectar la unidad al suministro eléctrico Es importante que el voltaje de la unidad coincida con el voltaje de red 6 Entrada de alim...

Page 14: ...or eso es recomendable utilizar un terminador en todos los casos Si el funcionamiento de la unidad no es adecuado especialmente cuando se utilizan cables de señal prolongados el uso de un terminador puede ayudar a mejo rar el rendimiento del dispositivo Construcción de terminador DMX Conecte un resistor de 120 Ω y 1 4 W entre los pins 2 y 3 de la última unidad Puede adquirir este resistor en un es...

Page 15: ...ial y pistas Elimine el cross fade entre escenas en el controlador Falta de terminación de la conexión de datos Inserte un conector de terminación en la salida de la última unidad Unidad defectuosa o 2 dispositivos con trans misión en la misma conexión Omita las unidades de a una por vez has ta que vuelvan a funcionar normalmente Desenchufe ambos conectores y conéctelos juntos de manera directa Fa...

Page 16: ...ad de destellos velocidad creciente 8 C C000 C255 velocidad de sombreado del color velocidad creciente 9 J J000 J255 velocidad de salto del color velocidad creciente 10 S S000 S255 velocidad de la activación por sonido velocidad creciente 11 d Modo DMX de 11 canales requiere conexión a controlador DMX 12 d Modo DMX de 7 canales requiere conexión a controlador DMX Canal Función Descripción CH1 Dimm...

Page 17: ...ción Descripción CH1 Dimmer Dimmer RGBAUVW oscuro brilloso CH2 Dimmer R Dimmer rojo lineal oscuro brilloso CH3 Dimmer G Dimmer verde lineal oscuro brilloso CH4 Dimmer B Dimmer azul lineal oscuro brilloso CH5 Dimmer A Dimmer ámbar lineal oscuro brilloso CH6 Dimmer U Dimmer lineal UV oscuro brilloso CH7 Dimmer W Dimmer lineal blanco oscuro brilloso CH8 Flash Ajuste de velocidad de destellos velocida...

Page 18: ...FOR MORE INFO ON THIS PRODUCT PLEASE CHECK WWW TEC SHOW COM PARA MÁS INFORMACIÓN SOBRE ESTE PRODUCTO VISITE WWW TEC SHOW COM ...

Reviews: