Installation guidelines
TS1061 Dual Wiegand Interfaces are designed, assembled and tested to comply
with the requirements related to safety, emission and immunity with respect to
environmental electrical and electromagnetic interference, as of current
applicable codes, when installed according to the requirements in this manual.
In addition to the general installation guidelines, installers must adhere to any
country dependent requirements of local applicable standards.
The TS1061 Dual Wiegand Interface is designed to be used with the
Challenger
Plus
and Network Access Controller, and must be installed as
described in the Installation Manual of the panel it is connected to.
• Circuit separation, conduit materials, and workmanship are to comply with
all applicable codes and regulations.
• Only use units in a clean dry indoor environment, as described on page 1.
• Installation must be performed in accordance with AS/NZS 2201.
Installation procedures
The TS1061 Dual Wiegand Interface must be installed in the ENC-LGE Large
Enclosure.
Mounting in the enclosure
The installation procedure is as follows:
1. Install four standoff board mounts for the TS1061 board on the enclosure.
Refer to the
ENC-LGE Large Enclosure Installation Manual
for mounting
locations. Figure 9 on page 18 indicates some possible mounting locations in
the enclosure.
2. Remove the TS1061 board from its antistatic bag.
3. Use four M3 x 10 pan head screws
to fix the board to the enclosure’s
standoffs.
4.
Slide the board’s terminal connectors together and mount them to the board.
5. Configure the
Interface’s address using the Address DIP switch. Refer to “DIP
switch settings