Configure UltraSync on Challenger panel
To configure UltraSync on Challenger panel:
Go to CTPlus -> Panel programming ->Communications ->UltraSync
options.
On the Setup tab, tick the “Enable UltraSync” and the “Enable Ethernet
path” checkboxes.
Path: Configured Ethernet path is assigned by default. If you would like to
change the default selection, choose another configured communication
path (Ethernet or GSM) by clicking the Browse button or type the path
number directly into the field.
URL and Port info have default values and should only be changed if
advised by tech support.
In addition to the Ethernet path, you can enable the radio path and use it
as a backup to the Ethernet path. This will take up to two paths.
Enter the 8 digit UltraSync passcode.
To grant full access to CTPlus via UltraSync, parameters in below are
enabled by default.
o
Allow remote connection
: Enables remote access (Ethernet or
GSM) to CTPlus via UltraSync.
o
Allow programming if any area is armed
: If not enabled, user
cannot modify the ChallengerPlus database using CTPlus until all
areas are disarmed.
o
Allow remote control
: If not enabled, users cannot run CTPlus
operations (open door, lock door etc.) via UltraSync connection.
o
Allow firmware upgrade if any area is armed
: If not enabled,
users cannot upgrade the ChallengerPlus firmware via UltraSync
connection until all areas are disarmed.
Figure 13 UltraSync Configuration