Teco Australia Pty Ltd will not warrant the equipment supplied, if  the 

installa�on does not 

 comply with 

the Building Code of Australia or any Local Government  standard or code. The customer/contractor is solely 
responsible for ensuring that the equipment installed complies with all relevant building codes or standards.

IMPORTANT NOTICE

CAUTION

Due to various wall and window types and construc ons, Teco Australia Pty Ltd recommends the window/wall  

type room air condi oner must be installed with compliance to the Building Code of Australia, Local Government 

or body corporate requirements. Please consult your local builder or air condi oning  contractor.

 

All hardware required to install the air condi oner is 

eld supplied.

 

Drainage

 

8

the condenser coil during opera�on. Draining water away from the base may cause a slight loss in 

performance.

1.

Thermosta�cally controlled drain mechanism. The drain will open <14 C (approx.) to allow water

to drain from the base and will close >15 C (approx.).

2.

Drain hole with rubber plug fi�ed

The Cooling model has only one drain hole with rubber plug fi

ed.

Please remove the rubber plug fi�ed

 

to the drain hole if the noise of splashing water bothers you or if

the water droplets splashed through

 

the condenser coil drops  to the ground below causes a trip hazard

or during Winter to release

 

defrosted water quickly from the base.

To install a drain line please follow the steps below:

1.

Slide out the chassis from the cabinet.

2.

Remove the rubber plug from the body base plate.

3.

Install the drain pan to the corner of the cabinet with 2 screws.

4.

Slide the chassis into its original place in the cabinet.

5.

Connect the drain hose (field supplied) to the outlet on the drain pan bo�om.

WARNING:

 Do not push any object into the condensate drain hole as it may damage the condensa�on

water thermostat mounted above.

Drain Hole

s

Drain Plug

The cooling and heating model has two drain holes:

(

For illustration

purposes only

)

Summary of Contents for TWW16CFDG

Page 1: ...Manual should be read carefully before using your air conditioner After reading store it in a safe place Please refer to the manual for questions on use or in the event that any irregularities occur U...

Page 2: ...expense you might incur as a result of the use of or reliance on information provided It is not intended to be and should not be relied upon as the ultimate and or complete source of information WARNI...

Page 3: ...dex Safety Precau ons 4 Func ons 6 Opera ng Condi ons 7 Installa on 8 Part Iden ca on 11 ControlPanel 12 RemoteControl 13 Opera onTips 16 GeneralOpera on 17 Care Maintenance 19 Troubleshoo ng 20 3 Ind...

Page 4: ...the required safety of the appliance e g danger of overheating this can result in re and or electric shock Do not damage or modify the power cord or plug Do not tamper with tie or twist the power cord...

Page 5: ...awaterleakage Do not use the appliance in places that may be subject to oil or ammable gas leakage Such a leakage around the appliance may cause combustion and re Do not wash the appliance with water...

Page 6: ...ng hot summer days the air condi oner can cool down the room by circula ng the air within the room and cooling it In wet or humid condi ons the air condi oner can dehumidify the air by drawing moistur...

Page 7: ...on outside these air on temperature ranges may e ect the performance of the air condi oner Power Requirements Rated voltage and voltage range 220 240V The electric components could be damaged when the...

Page 8: ...controlled drain mechanism The drain will open 14 C approx to allow water to drain from the base and will close 15 C approx 2 Drain hole with rubber plug ed The Cooling model has only one drain hole w...

Page 9: ...below Internal Clearances A clear area is necessary around the interior of the cabinet to allow adequate air ow through the unit The minimum clearances required are shown below 9 500mm 500mm Unobstruc...

Page 10: ...ews from either side and middle of front panel d Push into sides and top of metal casing to releas clips and remove front panel 2 Remove Cabinet screw 10 r Removal Procedure e Remove scre and clasp fi...

Page 11: ...in Control Knob Set to select Low Cool Med Cool High Cool or Fan Only as desired CAUTION WAIT at least 3 minutes before resetting to cooling operation if it has been turned off or set to Fan 2 Thermos...

Page 12: ...the light will go o If the lter requires cleaning prior to the 250 hours of operation remove clean and replace the lter To reset the timer press the Filter button for at least 3 seconds and the accumu...

Page 13: ...Only 3 button Under timer setting status after each pressing of or button time will Pressing or button once will increase or decrease set temperature by 1 C F Hold or button for 2s set temperature on...

Page 14: ...function This function is available in COOL HEAT Only for models with heating function mode to maintain the most comfortable temperature for you 7 Timer button Under ON status press this button to set...

Page 15: ...played on the remote No signal will be sent from the remote while it is in Child Lock Switching between ce rade and While the air conditioner is off press both MODE and buttons simultaneously to switc...

Page 16: ...hen the remote does not operate remove the batteries wait 30sec and replace them If problems persist replace with new batteries CAUTION Opera on in hea ngmode The amount of hea ng provided in HEAT mod...

Page 17: ...w direction to ensure uniform temperature in the room Make sure that the doors and windows are tightly closed Avoid opening doors and windows as much as possible to keep the conditioned air in the roo...

Page 18: ...appliance performance and causes irregular operation Do not use the appliance for Do not insert any objects into other purposes such as drying clothes orpreserving food etc these vents as it is dange...

Page 19: ...cleaning 2 Vacuum the lter onthe side containing the dust 3 Don t use gas benzene solvent cleanser chemical solvent etc for cleaning 3 Wash the lter cleaner side up under gentle owing water to wash o...

Page 20: ...ocked Othercooling heatingsourcesintheroom Check air lter is clean Indoor fan is set to LOW Room temperature is too high or too cool as the air conditioner starts or foggy air is released from the air...

Page 21: ...es Top Load Clothes Washers Front Load Clothes Washers Twin Tub Clothes Washers Auto Sensing Vented Clothes Dryers Refrigerators Chest and Vertical Freezers Bar Fridges Televisions Air Curtains and Ai...

Page 22: ...arry out servicing or repairs to this appliance IF SERVICE IS REQUIRED If you have a problem and the problem persists after you have made the checks mentioned in this manual contact TECO Australia s S...

Page 23: ...www teco com au GCA v7...

Reviews: