Foreword 

Congratula

Ɵ

ons on your purchase of a TECO room air condi

Ɵ

oner. To assist you in protec

Ɵ

ng your investment and

 

maintaining the appliances sa

Ɵ

sfactory opera

Ɵ

on, three simple steps are provided for you to  follow.

 

They are:

 

1. Ensure that your air condi

Ɵ

oner is installed according to the speci

Į

ca

Ɵ

ons detailed in this   booklet.

2. Familiarise yourself with the correct opera

Ɵ

on of the air condi

Ɵ

oners controls and   switches.

3. Maintain your air condi

Ɵ

oner at regular intervals.

Thank you for taking the 

Ɵ

me to read this booklet and we trust you enjoy the comfort obtained from your TECO

 

room air condi

Ɵ

oner.

 

The informa

Ɵ

on contained in this material is provided by Teco Australia Pty Ltd in good faith. The informa

Ɵ

on

 

supplied to our knowledge is correct; however is subject to change without no

Ɵ

ce, therefore before relying on    

the material in any important ma

Ʃ

er, users should carefully evaluate its accuracy, completeness and relevance for 

their purpose. It is not intended as a subs

Ɵ

tute for consul

Ɵ

ng the relevant legisla

Ɵ

on or for obtaining appropriate 

professional advice relevant to your par

Ɵ

cular circumstances.

 

Teco Australia Pty Ltd cannot accept responsibility or liability for any loss, damage, cost or expense you might

 

incur as a result of the use of or reliance on informa

Ɵ

on provided. It is not intended to be, and should not be relied 

upon as the ul

Ɵ

mate and/or complete source of informa

Ɵ

on.

 

WARNING ICON

This symbol indicates 
information concerning
your personal safety

CAUTION ICON

This symbol indicates 
information on how to avoid
damaging the appliance

FLAMMABLE ICON

This symbol indicates 
appliance filled with 
flammable R32 refrigerant

WARNING

CAUTION

R32

The Refrigerant 

R32

The refrigerant used in this appliance is the mildly flammable

HFC R32

 (difluoromethane). 

procedures

Compared to other commonly used refrigerants, R32 has a lower global warming potential 

and a zero ozone depleting potential. R32 has good thermodynamic features which lead 
to a really high energy efficiency. The units therefore require less refrigerant than 
previously used with other refrigerants.

If the refrigerant circuit should become damaged and a leak is observed, avoid open 

 of

ignition.

Disconnect the power to the appliance from the mains power. As this appliance uses a plug to 

supply power do not switch off from the appliance controls or the power point.

Thoroughly ventilate the room in which the appliance is situated for several minutes before using

other appliances or sources of ignition.

Contact TECO customer service for advice.

WARNING

2

Read Before Use

Read Before

Installation

Read Before 

Servicing

Summary of Contents for TWW16CFCG

Page 1: ...nsure satisfactory operation for many years to come this User s Manual should be read carefully before using your air conditioner After reading store it in a safe place Please refer to the manual for...

Page 2: ...nse you might incur as a result of the use of or reliance on informa on provided It is not intended to be and should not be relied upon as the ul mate and or complete source of informa on WARNING ICON...

Page 3: ...dex Safety Precau ons 4 Func ons 6 Opera ng Condi ons 7 Installa on 8 Part Iden ca on 10 ControlPanel 11 RemoteControl 12 Opera onTips 16 GeneralOpera on 17 Care Maintenance 19 Troubleshoo ng 20 3 Ind...

Page 4: ...lable from the manufacturer orTECO service center Do not put your ngers or any objects into the air outlet and inlet Please do not touch the swing louvres The internal fanrotates at a high speed andth...

Page 5: ...erleakage Do not use the appliance in places that may be subject to oil or ammable gas leakage Such a leakage around the appliance may cause combus on and re Do not wash the appliance with water It ma...

Page 6: ...ng hot summer days the air condi oner can cool down the room by circula ng the air within the room and cooling it In wet or humid condi ons the air condi oner can dehumidify the air by drawing moistur...

Page 7: ...on outside these air on temperature ranges may e ect the performance of the air condi oner Power Requirements Rated voltage and voltage range 220 240V The electric components could be damaged when the...

Page 8: ...sh the condensa onwateronthecondensercoil The cooling hea ng model has a thermosta cally controlled drain mechanicism The drain will open 14o C approx to allow water to ow from the base of the unit an...

Page 9: ...sh air ow through the unit The minimum clearances required are shown below Internal Clearances A clear area is necessary around the interior of the cabinet to allow adequate air ow through the unit Th...

Page 10: ...in Control Knob Set to select Low Cool Med Cool High Cool or Fan Only as desired CAUTION WAIT at least 3 minutes before resetting to cooling operation if it has been turned off or set to Fan 2 Thermos...

Page 11: ...on and the light will go o If the ter requires cleaning prior to the 250 hours of opera on remove clean and replace the lter To reset the mer press the Filter bu on for at least 3 seconds and the acc...

Page 12: ...e remote control Do not place the remote control in direct sunlight or any loca n with excessive heat 1 ON OFF button 2 3 4 5 6 7 MODE button 1 3 4 2 button 5 FAN button SWING button 6 7 SLEEP button...

Page 13: ...t be displayed either Press FAN button to adjust fan speed When selecting cool mode air conditioner will operate under cool mode Then press or button to adjust set temperature Press FAN button to adju...

Page 14: ...is unavailable 7 TIMER button When unit is on press this button to set Timer Off T OFF and H icon will be blinking Within 5s press or button to adjust the time for Timer Off Pressing or button once wi...

Page 15: ...played on the remote No signal will be sent from the remote while it is in Child Lock Switching between ce rade and While the air conditioner is off press both MODE and buttons simultaneously to switc...

Page 16: ...wireless appliances x When the remote does not operate remove the batteries wait 30sec and replace them If problems persist replace with new batteries N Battery Cover of battery box Remove Reinstall...

Page 17: ...r ow direc on to ensure uniform temperature in the room Make sure that the doors and windows are htly closed Avoid opening doors and windows as much as possible to keep the condi oned air in the room...

Page 18: ...appliance performance and causes irregular operation Do not use the appliance for Do not insert any objects into other purposes such as drying clothes orpreserving food etc these vents as it is dange...

Page 19: ...leaning 2 Vacuum the ter onthe side containing the dust 3 Don t use gas benzene solvent cleanser chemical solvent etc for cleaning 3 Wash the ter cleaner side up under gentle owing water to wash out a...

Page 20: ...ing hea ngsourcesintheroom Check air lter is clean Indoor fan is set to LOW Room temperature is too high or too cool as the air condi oner starts or foggy air is released from the air condi oner When...

Page 21: ...othes Washers Front Load Clothes Washers Twin Tub Clothes Washers Auto Sensing Condenser and Vented Clothes Dryers Refrigerators Chest and Vertical Freezers Bar Fridges Dehumidifiers Televisions Air C...

Page 22: ...arry out servicing or repairs to this appliance IF SERVICE IS REQUIRED If you have a problem and the problem persists after you have made the checks mentioned in this manual contact TECO Australia s S...

Page 23: ...www teco com au BG 9...

Reviews: