BATTERY MODE 

The UPS automatically runs in BATTERY mode if the Mains Voltage amplitude gets out of 

security limits (in case of a black-out or overvoltage-lowvoltage): in this case, the UPS supplies 

the required output power by its internal battery and by the DC/DC CONVERTER, BOOSTER and 

INVERTER blocks (see figure 1). 
The UPS automatically returns to function in LINE mode a few seconds after the AC input line is 

recovered. 
The BATTERY mode is characterized by: 

 

 

An acoustic signal every 4 seconds indicating that the batteries are discharged. The acoustic 

signal can be disconnected by pressing the ON/TEST/ALARM button.  

 

The INVERTER led and BATTERY led switched ON. 

 

The LOAD LEVEL and BAT. LEVEL led bars are switched on. 

BYPASS MODE 

In BYPASS mode (see figure 1), the AC input line is directly connected to the UPS outlets by an 

AUTOMATIC BYPASS. 
EVO RT uses the BYPASS mode during the start-up phase; furthermore the UPS switches 

automatically to BYPASS mode in consequence of accidental overload or Inverter fault thus 

protecting the supplied devices. 
The BYPASS mode is characterized by: 

 

The BYPASS led and LINE led switched on. 

 

The LOAD LEVEL and BAT. LEVEL led bars switched on. 

 

The UPS can be transferred in BYPASS mode even through a manual operation. 
First of all one must be sure that the UPS is working properly in LINE mode. The manual 

BYPASS switch is positioned on the rear side of the product (see figure 3)If this switch is in 

the ON position (BYPASS), the UPS changes in BYPASS mode and indicates this condition with: 

 

The BYPASS led and LINE led switched on. 

 

The entire LOAD LEVEL led bar switched on, the red OVERLOAD and FAULT Leds switched on. 

 

Continuous acoustic alarm. 

 
The UPS starts working again normally when the OFF switch is in (NORMAL) position. Acoustic 

alarm stops immediately and the UPS carries out an operating SELF TEST (during which the red 

FAULT and OVERLOAD Leds are switched on). After a few seconds the BYPASS led is switched 

off and the INVERTER led is switched on: this indicates that the UPS has started working 

normally in LINE mode. 

During the above mentioned operations, the devices powered by UPS will continue working 

regularly  

WARNING 
BYPASS operations must be carried out ONLY by qualified Technical personnel 

specialised and authorised by Tecnoware. 

LOW BATTERY AND AUTOMATIC RESTART  

In BATTERY mode, EVO RT indicates the LOW BATTERY condition whenever the battery 

reaches a charge level allowing connected devices to operate for approximately one more 

minute.  

UPS EVO RT 

10 User’s 

manual

 

Summary of Contents for EVO 1.0 RT

Page 1: ...EVO RT Uninterruptible Power Supply EVO 1 0 RT EVO 2 0 RT EVO 3 0 RT USER S MANUAL...

Page 2: ......

Page 3: ...EIPT OF UPS PLACEMENT FIRST START UP 5 COMPUTER INTERFACE page 12 6 TECHNICAL CHARACTERISTICS page 13 7 SUGGESTIONS FOR A CORRECT USE page 14 MAINTENANCE BATTERY MAINTENANCE BATTERY REPLACEMENT HOT SW...

Page 4: ...repair or maintenance must be performed exclusively by qualified technical personnel authorized by TECNOWARE TECNOWARE declines any responsibility if this warning is disregarded It is compulsory to g...

Page 5: ...used to signal to a generic processor or computer the absence of mains supply or the end of battery autonomy This permits to carry out an automatic data saving operation during a long black out with t...

Page 6: ...ning test through a switch Automatic regulation to the input frequency 50 or 60 Hz Visual warnings by leds indicating operational mode and low battery overload and alarm conditions Dry contacts board...

Page 7: ...blue led is ON when the input AC line voltage amplitude is within the specification and it indicates the UPS is working in LINE mode If LINE led flashes every second it means that the Phase line and...

Page 8: ...8 60 41 three leds are on Led15 16 and 17 40 21 two leds are on Led15 and Led16 20 0 only one led is on Led15 The LOW BAT yellow led Led14 is on to warn of a LOW BATTERY condition during BATTERY mode...

Page 9: ...from the front panel The EPO terminals are isolated and do not need an external feeding voltage REMOTE ON OFF ON 1 2 Remote Button ON OFF 3 4 Remote Button OFF The EVO models have remote ON OFF termi...

Page 10: ...n 6 is normal closed output When UPS works normally Pin 6 and Pin 1 2 will be closed when UPS works in bypass mode Pin 6 and Pin 1 2 will be open 4 AC fail Pin 7 is the normal open output When UPS wor...

Page 11: ...owing its switching on The UPS immediately switches on the BAT LEVEL bar then carries out an initial operating SELF TEST during which the red FAULT and OVERLOAD leds are switched on The UPS switches o...

Page 12: ...bars switched on The UPS can be transferred in BYPASS mode even through a manual operation First of all one must be sure that the UPS is working properly in LINE mode The manual BYPASS switch is posit...

Page 13: ...EVO RT automatically switches to BYPASS mode as soon as the overload is higher than 150 Once the requested power is back within range EVO RT automatically switches to LINE mode again In BATTERY mode...

Page 14: ...fications and check that the selected area meets these criteria EVO RT requires at least 20 cm of unobstructed space all around in order to be properly ventilated The UPS is designed to be fitted insi...

Page 15: ...ver The UPS contains internal parts which are at a high voltage and are potentially dangerous capable of causing injury or death by electric shock There are no internal parts in the UPS which are user...

Page 16: ...ATTERY VOLTAGE 36 Vcc 96 Vcc 96 Vcc SEALED MAINTENANCE FREE LEAD ACID BATTERIES 3 units 12V 7 2Ah 8 units 12V 7 2Ah 8 units 12V 7 2Ah TYPICAL BATTERY CHARGE TIME 8 Hours EXPANDABLE AUTONOMY Included H...

Page 17: ...excellent state and extend the life duration Leave the UPS in BATTERY mode until the end of autonomy condition is reached After which restore the input mains The UPS will return functioning in LINE mo...

Page 18: ...all cover screws 11 Insert again the battery box into its own place 12 Screw the 4 screws again at the corners of the battery box front side 13 Fasten left part of the battery connector to the right p...

Page 19: ...Before you go on to the next operations switch the UPS OFF and remove the UPS input voltage Check the condition of every feeding cables and their right connection The UPS indicates OVERLOAD Check whi...

Page 20: ...19 FIGURES Figure 1 Operating modes Top diagram NORMAL OPERATION Middle diagram BATTERY OPERATION Bottom diagram BYPASS OPERATION UPS EVO RT 18 User s manual...

Page 21: ...ERLOAD led red 9 LOAD 100 led blue 10 LOAD 80 led blue 11 LOAD 60 led blue 12 LOAD 40 led blue 13 LOAD 20 led blue Operating modes leds BAT level led bar 3 LINE led blue 4 BATTERY led blue 5 BYPASS le...

Page 22: ...3 Grounded output socket 4 Grounded power output socket EVO 2 0 and EVO 3 0 5 Computer Interface RS 232 6 RJ11 RJ45 IN OUT plugs 7 Slot for external batteries connector 8 Dty contacts board Slot for...

Page 23: ...in any case any circumstances in which one cannot date back to the defective manufacture will not be covered by the guarantee Compensation is excluded for direct or in direct damages of any nature ca...

Page 24: ...TECNOWARE S r l www service tecnoware com...

Reviews: